14
|
Evolve 950 Installation Guide: 12471-A 01-14
Install heater into enclosure
1. Carefully move the heater into the enclosure, guiding the piping, flexible gas connection, and
telescopic extension tube into the access openings and through the appliance. Ensure that the air
hose is not in a position where it could get caught or crushed by the unit.
2. Once the engine is in place reconnect the flue exhaust to the telescopic extension tube and secure
together with the pipe clamp.
3. Secure the heater flange in place using the 11 seismic constraint screws provided.
4. Complete gas, air hose, and flue connection. If vertically flueing ensure condensate tube, provided
with the EVOKIT03 flue kit, is attached to the condensate pipe on the heater—refer images below.
Please note:
The unit is supplied with the heater condensate already connected.
Pipe clamp
Telescopic extension tube
Flue exhaust
Flange screw position
—
11 in total
Flue condensate pipe connection
The engine comes with the heater condensate already connected.