– 29 –
■
TYPES COMPATIBLE WITH EXTENSION KIT
RHFE - 556FTR / 556T
INSTALLING AN EXTENSION KIT
Installing an extension kit requires construction of an air line and the exhaust line. The air line is
connected between the Air Supply Elbow at the rear of the heater and the air inlet port on the Flue pipe.
Similarly, the exhaust line is connected between the joint pipe at the rear of the heater, and the exhaust
port on the Flue pipe.
Caution: Check to see there is no debris in pipe or hose.
■
HOW TO INSTALL
MODEL: RHFE - 556FTR / 556T
Example: Using 2 sets of extension kit and 1 bend kit.
Example: Using 2 Metre side pipe kit.
Mushroom Flue
(comes with main unit)
Air intake elbow
(comes with main unit)
Pipe stopper A
Pipe stopper B
Pipe stopper A
Bent elbow
Pipe stopper A
Hose joint
Pipe stopper B
Exhaust pipe
Hose joint
Pipe stopper A
Pipe stopper B
Air intake hose
Mushroom Flue
(comes with main unit)
Air intake elbow
(comes with main unit)
Pipe stopper A
Pipe clamp
Pipe stopper B
Pipe clamp
Pipe clamp
Exhaust pipe
Pipe stopper A
1 metre straight pipe
Pipe clamp
Pipe stopper A
Pipe stopper B
Hose joint
Air intake hose
Pipe clamp
IMPORTANT NOTE:
When the appliance is installed using a flue extension that exceeds 1.8 metres you must
change the link on the flue extension
terminal block as shown.
Terminal is located at the rear of unit
next to gas inlet.
1
2
3
FOR DIRECT
EXHAUST
USED FOR EXTENSION KITS