CARING FOR YOUR NEW RHFE-556T

This appliance is safely controlled.  If there is something wrong then it will stop, as it is protected by
the following safety devices.

Ignition Safety Device

Power Failure Safety Device

Burner Safety Device

Power Surge Safety Device

Overheat Safety Device

Fan Delay Safety Device

Your RHFE-556T requires very little maintenance,
simply clean the rear fan filter once a week and wipe
the outer case and louvre section with a damp cloth.

DO NOT USE SOLVENTS.

Solvents may melt or distort plastic parts.

Problem

Cause

Not Plugged In

Power Cut

(Initial Installation)
Air in gas pipe

Gas Filter Blocked

Missed Ignition

Flue terminal obstructed

Flue manifold not connected

Louvre obstructed

Air filter blocked

Gas Escape

Gas turned off at meter

Remedy

No ON indicator

Burner doesn't ignite

Unusual

combustion

Combustion stops

during operation

Smell of gas

Noisy Ignition

Takes too long to

warm the room

Remote control

doesn't work

Plug In

Re-ignite manually after
power is restored

Purge air
(Installer)

Service Call

Service Call

Clear obstruction

Service Call

Clear obstruction

Clean filter (weekly)

Service Call

Turn gas on

Содержание Energysaver RHFE-556T

Страница 1: ...56T RHFE 556T Energysaver Space Heater Operation and Use Page 2 Installation Page 12 Important Read these instructions carefully before attempting installation or use of this appliance All work must b...

Страница 2: ...7 Adjusting Temperature 8 Humidifier 9 Wiring Diagram 23 Gas Conversion 24 Extension Kits 28 Service Contact Point 33 Rinnai Corporation Japan Manufactured under a Quality System Certified as complyi...

Страница 3: ...hich is operating normally may be chargeable even when the heater is under warranty The installer is responsible for your heater s correct installation There is no requirement to post the following in...

Страница 4: ...ifies the warm air flow BOTTOM TRIM Pulls off to allow filling of humidifier tray LOUVRE Warm air discharge duct CONTROL PANEL for ON OFF And Room Temp Control AIR FILTER Helps to protect the interior...

Страница 5: ...20 22 24 26 HI ON OFF Room adjustment Room temp indicator ON FILTER POWER ON COMBUSTION INDICATOR Indicates that the appliance is turned ON and whether the burner is alight FILTER INDICATOR Indicates...

Страница 6: ...cessary strain on the appliance FILTER INDICATOR WARM AIR DISCHARGE Warm air flows from the bottom of the appliance through the louvres assisting in even heat distribution An integral humidifier tray...

Страница 7: ...r is operating Most aerosols contain butane gas and can be a fire hazard if used near this heater when it is in use Flue Guard must be fitted if indicated on page 17 Do not allow curtains or other fla...

Страница 8: ...at regular intervals It is strongly recommended that a guard is fitted around heater where there are young children elderly infirm or handicapped persons Do not place articles containing liquids on to...

Страница 9: ...If the heater does not ignite on initial use this may be due to air remaining in the gas supply line The spark generator will only continue for 15 seconds After this it will be necessary to press the...

Страница 10: ...6 18 20 22 24 26 HI ON OFF Room adjustment Room temp indicator ON FILTER POWER ON COMBUSTION INDICATOR Indicates that the appliance is turned ON and whether the burner is alight FILTER INDICATOR Indic...

Страница 11: ...gently bending the vertical louvre s either to the left or the right Note these louvres are not designed to be adjusted more than 6 times So that you can humidify the air your Rinnai RHFE 556T is fitt...

Страница 12: ...T USE SOLVENTS Solvents may melt or distort plastic parts Problem Cause Not Plugged In Power Cut Initial Installation Air in gas pipe Gas Filter Blocked Missed Ignition Flue terminal obstructed Flue m...

Страница 13: ...fan continues to run after turning OFF This is to remove the residual heat from the heat exchanger the fan will stop when the heater cools down Other Points Steam is discharged from the flue terminal...

Страница 14: ...r your Supplier and arrange for a service call CODE DISPLAYED FAULT Missed Ignition 16 LO 20 HI 22 24 24 26 18 20 22 20 22 24 LO 16 18 16 18 20 18 20 LO 16 26 22 24 26 HI Flame failure Overheat Room o...

Страница 15: ...rrent issue of a Building Regulations issued by the Dept of the Environment and Building Standards Scotland Consolidation Regulations b I E E Wiring Regulations for electrical installations c Gas Safe...

Страница 16: ...information and Installation Instructions Air Filter Flue Securing Screws Wall Bracket Screws For Flue Lock Stopper For Air Intake Clip For Back Spacer Set M4 M4 Angle Bracket Flue Locking Clamp Flue...

Страница 17: ...ith it In some cases curtains may need restraining See diagram for other recommended clearances Flue fittings must be kept clear of flammable materials This heater is not designed to be built in The f...

Страница 18: ...ust be fitted and these are available from your supplier FLUE SIZES 6 Flue lengths are available S flue suits wall 75 115 mm A flue suits wall 115 240 mm B flue suits wall 240 400 mm C flue suits wall...

Страница 19: ...car port roof From a vertical drain pipe or soil pipe From an internal or external corner Above ground roof or balcony level From a surface facing the terminal From a terminal facing a terminal From...

Страница 20: ...in the shaded area To avoid studs etc Before drilling the flue hole check for water and gas pipes as well as electric cables Use an 80mm 8cm drill for hole through wall MOUNTING TO WALL Assemble Angle...

Страница 21: ...nt 3 For A and S flues only Depending on flue set and wall thickness extension piece C may need to be removed Cut plastic remove extension then follow instruction 2 This applies to A and S flues only...

Страница 22: ...lugs inside sleeve You should be able to pull ties 2 or 3 slots past the starting point Cut the ties leaving about 20 mm past the lugs Bend ties so they are parallel with the wall 8 Insert Inner Conne...

Страница 23: ...ed line Manifold 2 Fit the locking clamp over connection between sliding tube and manifold Engage the hook and rotate it until it snaps against the body of the clamp Locking clamp Flue outlet Sliding...

Страница 24: ...of switch on the electrical supply apart from the means of isolating the supply for servicing A clock or switch would also turn OFF the convection fan causing overheating 3 On the rear right hand sid...

Страница 25: ...23 RINNAI 1004T 556T WIRING DIAGRAM USING RANDALL 851 PROGRAMMER N L N L RANDALL 851 TIMER RINNAI 556T 10 1 transformer Rinnai UK Part number 957 000 001 RINNAI 1004T RINNAI 1004T L N L N...

Страница 26: ...screws take care with gasket 10 Carefully remove front damper 1 screw see drawing 4 11 Using pointed nose pliers carefully pull the right hand damper forward and out of the burner assembly 12 Gently f...

Страница 27: ...the remote clock if fitted see page 21 and check appliance operaton When appliance is on check test points for gas tightness THE REGULATOR HAS BEEN FACTORY PRE SET IF THE PRESSURE IS INCORRECT CHECK T...

Страница 28: ...Tighten all screws fit fan filter Fan filter Adjustable Leg Up to 10 mm Levelling screws Adjustable legs If necessary the unit can be levelled using the adjustable legs under the front right and left...

Страница 29: ...y gy gy gy gy gy 5 4 7 6 K w bk w bk bk r r INDICATOR CONTROL DISPLAY UNIT CONTROL DISPLAY CIRCUIT TEMP CONTROL CIRCUIT CENTRAL TIMER CONTROL CIRCUIT CENTRAL TIMER CONTROL SUB P C B TH AC24V TB1 556T...

Страница 30: ...XHAUST PIPE STRAIGHT 1 Metre CAIR INTAKE HOSE DBENT ELBOW EHOSE JOINT FPIPE STOPPER A GPIPE STOPPER B HPIPE CLAMP IWALL FIXTURE JNUT KSCREW A LSCREW B L 600 LONG FLEX TUBE A C B A B A B C D E F G H I...

Страница 31: ...ide pipe kit Mushroom Flue comes with main unit Air intake elbow comes with main unit Pipe stopper A Pipe stopper B Pipe stopper A Bent elbow Pipe stopper A Hose joint Pipe stopper B Exhaust pipe Hose...

Страница 32: ...roughly deburr all rough edges Main unit air intake hose Air intake hose Hose joint Screw in counterclockwise Air intake hose Air intake elbow Pipe stopper A Fit inside Connect bent pipe Female end Ma...

Страница 33: ...pipes leave the body is not counted The air intake hose should run along the exhaust pipe 3 Condensed water formed by combustion will run back to the unit and may overflow from the condensation pan i...

Страница 34: ...er the air intake hose and exhaust pipe run sideways try to have the exhaust pipe on top to prevent the air intake hose from sagging onto the exhaust pipe Exhaust pipe Exhaust pipe Air intake hose Air...

Страница 35: ...50 214 R279 R 2 0 6 217 245 632 750 WALL OPENING RANGE AIR SUPPLY CONNECTION 554 280 280 77 85 165 GAS CONNECTION 134 36 Contact Rinnai UK Ltd 9 Christleton Court Manor Park Runcorn WA7 1ST Tel 01928...

Страница 36: ...Jan 2006 556F 2190...

Отзывы: