Vent Extension Installation Guidelines
MOUNTING COMPONENTS
1. Both the exhaust and air intake extensions are supported by clamps which are
attached to the wall. A wall fixture can be used to offset the clamp from the wall. A
one inch clearance from combustibles should always be maintained from the
exhaust. The clamps provided with the extension kit ensure this clearance is
maintained from the wall and the air intake.
2. If extension are installed horizontally, the air intake hose should be underneath the
exhaust so in the event the air intake sags, it will not contact the exhaust.