![Rinnai Energysaver ES38 Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/rinnai/energysaver-es38/energysaver-es38_installation-fundamentals_1462573061.webp)
61
Vent Extension Installation Requirements
The following is an overview of guidelines and installation of Rinnai Direct
Vent Furnace vent extensions. This is not a substitute for any current
installation / owner’s manual or vent instructions.
• The 08 series can not use vent extensions.
• See each model’s owner’s / installation manual for permissible vent lengths.
• The vent termination must ALWAYS be horizontal.
• Vent extensions installed in ANY unconditioned air space MUST be insulated with high
temperature insulation and must be accessible.
• All pipe stoppers, connectors, screws and hangars must be used in accordance to their
instructions. The seals must be air tight for both the intake and exhaust air supply hoses.
• The intake air hose must equal the exhaust hose length to maintain a balanced flue system.
• The humidifier trays are made of enamel covered steel to resist rust and corrosion from the
condensate draining back to the unit.
• The 38 series tray cannot be removed from the unit.
• The 08, 11, 17, and 22 series trays can be removed for cleaning but must be replaced before
operation of the unit.
• Overflow of the humidifier tray is an indication that the venting extension was possibly installed
incorrectly. No warranty claim will be approved covering overflow.
Содержание Energysaver ES38
Страница 1: ...Rinnai ENERGYSAVER Direct Vent Wall Furnace Installation Fundamentals ...
Страница 30: ...30 View of Properly Installed Unit ...
Страница 50: ...50 Vent Termination OUTSIDE VIEW OF CORRECTLY INSTALLED TERMINATION ...
Страница 60: ...60 Extended Venting And High Altitude Installation Procedures ...
Страница 74: ...74 Decorative Covers For Vent Extension Kits ...