KBD Series Manual
47
Technical Data
Specifications
* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.
Minimum activation flow is 0.4 GPM (1.5 L/min).
Our products are continually being updated and improved; therefore, specifications are subject to change without prior notice.
The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value listed is for the
purpose of input adjustment.
RUC80i
RUC90i
RUC98i
RU80e
RU90e
RU98e
Minimum Gas Consumption Btu/h
15,200
Maximum Gas Consumption Btu/h
152,000
180,000
199,000
152,000
180,000
199,000
Hot water capacity (Min - Max) *
0.26 - 8.0 GPM
(1.0 - 25 L/min)
0.26 - 9.0 GPM
(1.0 - 29 L/min)
0.26 - 9.8 GPM
(1.0 - 32 L/min)
0.26- 8.0 GPM
(1.0 - 25 L/min)
0.26 - 9.0 GPM
(1.0 - 29 L/min)
0.26 - 9.8 GPM
(1.0 - 32 L/min)
Temperature Setting (no controller)
120° F (49° C) or 140° F (60° C)
Maximum Temp Setting (residential)
Selectable at 120° F (49° C) or at 140° F (60° C)
Maximum Temp Setting
(MCC-91-2 controller)
185° F (85° C)
Minimum Temperature Setting
98° F (37° C)
Weight
61.7 lb (28 kg)
Energy Factor
0.96
0.96
0.95
0.96
0.96
0.95
Noise level
41 dB
52 dB
Electrical Data
Normal
75 W
71 W
Standby
2 W
Anti-frost
Protection
146 W
168 W
Max Current
Without recirculation pump: 4 A
With recirculation pump: 8 A (exact value depends on the pump)
Fuse
10 A
By-Pass Control
Electronic
Gas Supply Pressure
Natural Gas
4.0 - 10.5 inch W.C.
Propane
8.0 - 13.5 inch W.C.
Type of Appliance
Condensing, Tankless, Temperature controlled continuous flow gas hot water system
Connections
Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT
Ignition System
Direct Electronic Ignition
Electric Connections
Appliance: AC 120 Volts, 60Hz.
Temperature Controller: DC 12 Volts (Digital)
Water Temperature Control
Simulation Feed forward and Feedback
Water Supply Pressure
Minimum Water Pressure: 50 PSI (Recommended 60-80 PSI for maximum performance)
Maximum Water Supply Pressure
150 PSI
Remote Control Cable
Non-Polarized Two Core Cable (Minimum 22 AWG)
Energy Star Qualified
Yes
Certified for installation in
manufactured (mobile) homes
Yes
Complies with South Coast Air
Quality Management District 14 ng/J
or 20 ppm NOx emission levels
Yes
Содержание Circ-Logic RU80e
Страница 50: ...50 KBD Series Manual Ladder Diagram ...
Страница 139: ......
Страница 140: ...Toll Free 1 800 621 9419 Phone 678 829 1700 www rinnai us t up 100000367 03 9 2014 ...