Operation
21/50
Pos : 10.6.10 / 7 Betrieb, Bedi enung/Sonder-Zubehör/Sammel behälter T yp RI 332 mit PE- Staubs ac k entleeren ( SB 100 Li ter) @ 4\ mod_1358323420930_131.doc x @ 37434 @ @ 1
Before emptying the dust container, switch off the device and wait for the motor to stop. Additionally,
the pocket filter "1" should be shaken off. Then wait for about 60 s until the dust has deposited in the
collection container.
•
Lower the dust container “3” with the lifting device "2" and pull it out.
•
Activate suction system again to prevent dust from escaping from the filter container by vibration.
•
Downholder remove "4"
•
Carefully pull the PE dust bag over the bead at the collection tank and close it tightly with cable ties
"7" (not included).
•
Remove PE dust bag "8" from the collection container.
•
If required, clean the collection container and insert a new PE dust bag (see wear parts list);
carefully push the edge over the bead at the collection container to avoid damage to the PE dust
bag.
•
Downholder insert "4"
•
Check the condition of the seal "5" at the filter container.
•
Switch off the suction system, then place the collection container "3" under the filter container,
while ensuring that you do not clamp in the pressure balancing hose "6", and lift with the lifting
device "2".
Pos : 11.1 /8 Stör ungss uc he und Stör ungs besei tigung/ St örungssuche und St örungsbes eitigung @ 0\ mod_1263801277821_131. doc x @ 1480 @ 1 @ 1