![Riken Keiki GP-147 Скачать руководство пользователя страница 73](http://html.mh-extra.com/html/riken-keiki/gp-147/gp-147_operating-manual_1461473073.webp)
Appendix Power Consumption Calculation Method and Simplified Safety Period Chart
- 73 -
[Calculating formula]
GP-147 (xx_point model)
Base unit and indicator unit
(1) A + B x __________ units = __________
Total detector heads: __________ units
Isobutane
sensor
(2) C x __________ units =__________
Methane
sensor
(3) D x __________ units = __________
Hydrogen
sensor
(4) E x __________ units = __________
Suction type detector head
(5) F x __________ units = __________
Power consumption (1) + (2) + (3) + (4) + (5) = __________
The safety period is approximately minutes according to the calculation result (W) and UPS battery
specification.
Note 1: The result obtained here for UPS should be used for reference.
2: Parallel running (addition) of UPS is prohibited.
3: As calculation conditions, the battery should be fully charged when discharge starts, and the
reading should indicate 0% LEL.
Simplified power consumption/safety period chart (following power consumptions apply to the case of
diffusion type, mounting all units and 0% LEL)
Quantity
Powered continuously
Powered intermittently
Isobutane sensor (HW-6211) used
Isobutane sensor (HW-6211) used
Power consumption
Safety period
Power consumption
Safety period
2
28.4 (VA)
5.4 (W)
600 minutes or
more
4.4 (W)
600 minutes or
more
4
36.0 (VA)
10.3 (W)
Approx. 270
minutes
8.3 (W)
Approx. 360
minutes
6
43.5 (VA)
15.2 (W)
Approx. 160
minutes
12.2 (W)
Approx. 210
minutes
8
52.1 (VA)
20.1 (W)
Approx. 100
minutes
16.1 (W)
Approx. 140
minutes
10
60.0 (VA)
25.0 (W)
Approx. 80
minutes
20.0 (W)
Approx. 110
minutes
12
67.0 (VA)
29.9 (W)
Approx. 60
minutes
23.9 (W)
Approx. 80
minutes
Methane sensor (HW-6239) used
Methane sensor (HW-6239) used
2
25.0 (VA)
4.6 (W)
600 minutes or
more
3.8 (W)
600 minutes or
more
4
32.9 (VA)
8.7 (W)
Approx. 340
minutes
7.1 (W)
Approx. 420
minutes
6
39.1 (VA)
12.8 (W)
Approx. 190
minutes
10.4 (W)
Approx. 250
minutes
8
45.5 (VA)
16.9 (W)
Approx. 130
minutes
13.7 (W)
Approx. 180
minutes
10
52.0 (VA)
21.0 (W)
Approx. 100
minutes
17.0 (W)
Approx. 140
minutes
12
58.4 (VA)
25.1 (W)
Approx. 80
minutes
20.3 (W)
Approx. 100
minutes
*The power consumption of the sensor is calculated assuming that the transmission distance between
detector heads is 100 m.