2

 

2. IMPORTANT INSTRUCTIONS FOR THE SAFETY

 

 
 
2−1.Danger cases 

 
2−2.Warning cases 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
2−3.Caution cases 

 
 
 
 
 
 
 
 
 

 
 
 
 
2−4.Caution for explosion proof (In case of intrinsically safe design) 

 
 
 
 
 
 
 
 
 

 

 
In case of non-explosion poof system, do not use this unit at the place where combustible gas 
may exist. 

 

 

・Do  not  cut  the  wire  for  protective  ground  both  inside  and  outside  of  instrument.  Or,  do  not  

disconnect the connection of the ground terminals. 

・Before starting the operation, check if any defect is not found on the protective grounding. 
・If there is any defect on the protective functions such as protective grounding, do not start the 

operation. 

・It is very dangerous if the instrument gives oxygen deficiency alarm. 

Take appropriate measures based on your judgment at that time. 

・Perform gas calibration at proper interval. 
・Do not change or remodel the circuit/structure of this unit. 
・Do not disassemble the sensor since there is a electrolyte inside. 
  If your finger touches the electrolyte, wash your finger away with water immediately. 

WARNING 

 
 
・Do not use a walky-talky around the instrument. 

The indication might be affected by the electromagnetic wave generated by the walky-talky if it is 
used near the instrument.    When the walky-talky is used, be away enough from the instrument 
not to affect. 

・Do not control other equipment by using outputs of this detector. 
  This is not control equipment.    It is prohibited to control other equipment by using outputs of 

this detector. 

CAUTION 

 
 
・Do not use this detector head expect for the measurement of oxygen content in a mixture of air 

and combustible gas or vapors, or a mixture of air and toxic gases. 

・When cleaning this unit, do not use dry cloth but use the wet  cloth not to change the static   

electricity on plastic part. 

CAUTION 

DANGER 

Содержание GD-F4A-1

Страница 1: ...ion for accidents and damage caused by using this product The indemnification shall be made only under the warranty policy of products or parts replacement Because this is a safety unit a regular main...

Страница 2: ...tector head 2 Alarm level for gas alarm instrument shall be set within the performance of the instrument Our standard alarm level is 18 by volume for the prevention of oxygen deficiency 3 This is not...

Страница 3: ...aution at piping works 10 Example of piping connection 10 HOW TO OPERATE Preparation for start up 12 How to start the detector head 12 How to exit 12 MAINTENANCE Maintenance intervals and items 13 Cal...

Страница 4: ...tor alarm unit to show oxygen content Read the operating manual for indicator alarm unit as well as this manual This unit is designed as drip proof construction for outdoor installation Also it can be...

Страница 5: ...interval Do not change or remodel the circuit structure of this unit Do not disassemble the sensor since there is a electrolyte inside If your finger touches the electrolyte wash your finger away with...

Страница 6: ...3 PRODUCT COMPONENTS External drawing Cable inlet Cable inlet Sensor Gas inlet Protective ground Gas outlet For U bolt Cable inlet Sensor Gas inlet Protective ground Gas outlet For U bolt...

Страница 7: ...yed terminal for sensor lead and external cable Cable gland Entrance to lead the cable 8 11mm from outside Hinge Hinge for front door Lock Lock for front door Mounting hole Mounting hole to fix this u...

Страница 8: ...ormance division and group Performance division ia Group C 3 Relations between allowable inductance Lo and allowable capacitance Co of intrinsic safety circuit and external wiring inductance Lw and ca...

Страница 9: ...inside detector head Drip proof housing Sensor lead Terminal strip Cable gland Shielded cable Oxygen sensor Gas inlet Gas outlet Detector head Indicator alarm unit Non hazardous area Non hazardous ar...

Страница 10: ...to get direct rays of the sun Places closed to high temperature and or emission of electromagnetic wave Place with vibration or shocks Place where the mounting part is weak and it is easy to come out...

Страница 11: ...t full lengths Cable O D 8 11mm Example of cable connection 1 In case of non explosion proof system Lead the applicable cable through cable inlet and connect to the terminal strip Connect the other si...

Страница 12: ...or alarm unit and be specified that it is for power interruption of indicator alarm unit Ground the zener barrier separately corresponding to the A class grounding with ground resistance of 10 or less...

Страница 13: ...G Use 8 O D 1t copper pipe and so on for piping Carry out piping works as straight as possible Excessively high load may cause burden on the suction pump shortening the effective life of the pump When...

Страница 14: ...hen the pump cannot be used If the sample gas pressure would fluctuate use the constant flow rate control valve to keep the constant flow rate Exhaust the sampled gas to open air in principle When mak...

Страница 15: ...ead sampled gas to 1 0L 0 3mL min Be sure to perform gas calibration at the time of new installation Correct reading may not be obtained before gas calibration How to exit Stop the sample gas supply t...

Страница 16: ...is also necessary to carry out gas calibration at least every 6 months The law in Japan sets forth that the unit must issue an alarm during the circuit maintenance related to alarm while providing no...

Страница 17: ...ag for calibration and confirm that the oxygen reading returns to 20 9vol Return disconnected piping to where they were completion of zero adjustment Performing a span adjustment Pack the span gas fre...

Страница 18: ...at the top of terminal strip and disconnect two lead black and white wires Loosen the screw for sensor stopper and take off the sensor stopper Pull out the sensor upward from the holder Insert new sen...

Страница 19: ...temperature 5 10 Environment of low oxygen content Put a sensor into the container and seal off the container List of recommendable spare parts for regular replacement No Name of parts Inspection fre...

Страница 20: ...rent proportional to the oxygen content permeated through the membrane Refer to 10 DETECTION PRINCIPLE for details Zener barrier Safety retainer for explosion protection by limiting the energy of elec...

Страница 21: ...Cable entry Cable gland Applicable cable O D 8 11mm Piping connection Rc 1 8 8 1t Provided with coupling Operating temperature 10 40 Operating humidity Below 90 RH Non condensing Structure Wall mount...

Страница 22: ...base metal electrodes immersed in an electrolyte with a lead wire an electrochemical cell is formed A membrane covers the cell and allows oxygen to diffuse into the electrolyte at a rate proportional...

Отзывы: