background image

6

Spare part overview article numbers

Nr. Art.Nr.

Description

1

L02007

Guide stone

2

N111965

Washer M05

3

N111866

Hexagonal screw

4

N111856

Hexagonal countersunk screw M04x12

5

L01957

Closure plate

6

L02010

Door lock

7

B16564

Door metallic assy

B16972

Door compleet, black

8

N103693

Flat seal black 8x2

9

Z34303

Door glass (ceramic glass)

10

N112551

Round sealing strip grey D11 (1m)

11

Z34472

Hinge plate

12

N112175

Washer

13

N103964

Hexagonal screw

14

Z34457

Hinge

15

N112075

Allen screw

16

L02574

Glass holder

17

N112551

Round sealing strip grey D11 (1m)

18

N111637

Setscrew door opener

19

N111798

Cylindrical pin door opener

20

B16565

Door opener assy

21

N112065

Cylinder screw

22

Z34554

Wood retainer metallic

Z36928

Wood retainer black

23

N111947

Self-tapping screw M05x16

24

Z34412

Firebrick lining front left

25

Z34411

Firebrick lining rear left

26

Z34553

Air scoop metallic

Z36252

Air scoop black

27

Z35555

Angle bracket and allen screw

28

B18224

Heat exchanger cover metallic

B16679

Heat exchanger cover black

29

N111320

Sealing cord grey D14

30

B16682

Flue gas chute lid

31

N103066

Round sealing strip black D06

32

Z36658

Baffle plate

33

Z34409

Firebrick lining rear

34

Z34410

Firebrick lining rear right

35

Z34413

Firebrick lining front right

36

N103560

Hexagonal screw

37

L02008

Fire trough tray

38

N111846

Hexagon socket 06x12

39

Z36643

Fire trough

40

Z34468

Sealing

41

Z36935

Seal

42

Z34244

Turning grid

43

L02044

Turning grid support

44

N112148

Hexagonal screw

45

L01875

Driving plate turning grid

46

N112470

Spring clip

47

N108131

Pressure spring

48

Z33924

Intermediate shaft turning grid

Nr. Art.Nr.

Description

49

N107521

Hexagonal screw M05x12

50

Z34824

Bearing clamping plate metallic

Z34965

Bearing clamping plate black

51

N104718

Circlips D08

52

N108310

Sinter bearing ID10

53

Z34757

Bearing plate top metallic

Z34966

Bearing plate top black

54

B16553

Sprocket top

55

N100172

Washer

56

N110928

Screw

57

Z34557

Chain turning grid

58

B16559

Actuating cam turning grid

59

N111825

Contact switch

60

Z34461

Bearing plate bottom metallic

Z34964

Bearing plate bottom black

61

N111631

Round sealing cord grey D06

62

B16680

Cleaning cover

63

N112093

Milled nut (cleaning cover)

64

B16957

Sprocket bottom

65

Z34555

Sinter bearing ID 10,2 sprocket out

66

L02952

Ash drawer

67

Z35158

Spacer chain guide / clamping plate

68

Z35302

Chain guide

69

Z35303

Clamping plate

70

B16675

Flap lever flue gas flap

71

N112283

Hexagonal screw

72

N112499

Setscrew with pin

73

Z36535

Shaft of fluegas flap

74

N103560

Hexagonal screw

75

Z36925

Bearing

76

Z36926

Shaft of fluegas flap

77

B18135

Lever fluegas flap

78

Z18997

Rubber buffer

79

N112321

Pressure spring

80

Z34471

Tension spring flue gas flap

81

B18087

Hinge shaft

82

N112120

O-ring

83

L02954

Holder plate

84

N111732

Magnetic switch top part

85

N111733

Magnetic switch bottom part

86

N112409

Hexagon socket screw

87

B17925

Flap handle

88

N112315

Cylindrical pin

89

B17340

Fluegas flap assy

90

Z34565

Soapstone option, lateral

91

B18082

Stone retainer

92

B16576

Convection cover metallic assy

B16965

Convection cover assy, black

93

E15143

Convection cover AH metallic

E15356

Convection cover AH black

94

B16577

Flue pipe cover metallic

B16966

Flue pipe cover black

Note: Please consider the powdercoated parts can differ slightly in colour and colour effects though they are elaborated in high quality�

Содержание induo II

Страница 1: ...INDUO II Operating manual...

Страница 2: ...are pellets 12 Wood pellet specification according to ENplus A1 12 Pellet container refilling during operation 12 Pellet storage 12 5 BRIEF INFORMATION ON COMBUSTIBLE LOGS 13 Suitable fuels and fuel...

Страница 3: ...surfaces 20 12 CLEANING 21 Cleaning the convection air openings 21 Combustion air intake 21 Cleaning the pellet container 21 Bearings 21 Checking door seal 21 Cleaning flue pipes 21 Cleaning flue gas...

Страница 4: ...am 7 8 9 16 15 11 11 11 12 12 13 13 5 5 18 4 4 20 19 17 10 14 14 6 1 1 2 2 3 3 21 66 28 27 29 33 25 34 24 35 32 26 30 31 39 42 37 36 38 22 23 48 47 45 46 50 53 51 52 54 57 67 68 69 55 56 49 64 65 52 5...

Страница 5: ...8 112 107 105 104 103 99 92 94 97 95 110 109 96 108 114 111 93 90 91 102 101 100 106 132 139 141 142 143 135 136 137 135 144 137 145 138 126 127 146 134 133 150 147 123 121 122 128 130 155 154 129 153...

Страница 6: ...rmediate shaft turning grid Nr Art Nr Description 49 N107521 Hexagonal screw M05x12 50 Z34824 Bearing clamping plate metallic Z34965 Bearing clamping plate black 51 N104718 Circlips D08 52 N108310 Sin...

Страница 7: ...Seal for ignition 123 Z34464 Insertion screw 124 B15248 Sensor tube 125 B16676 Flame temperatur sensor 126 L01954 Pressure bracket 127 N111862 Screw motor stepless 128 Z11915 Lock ring conveyer screw...

Страница 8: ...pacity l kg 51 33 Electric supply V Hz 230 50 Average electrical input W 20 Fuse A 2 5 T Pellet Operation Measure Data Heating capacity range kW 3 10 Efficiency in pellet mode 91 CO2 13 3 CO emission...

Страница 9: ...e embers together to form a firebed when you add new fuel logs Q Placing non heat resistant objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Laundry racks et...

Страница 10: ...Phone the fire brigade and get yourself and other residents out of harm s way Note Due to the size of the combustion chamber door it is necessary not to open the door abruptly to prevent the flames c...

Страница 11: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Страница 12: ...with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list of monitored fuel man...

Страница 13: ...particularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all softwoods and tends to spray sparks Wood t...

Страница 14: ...tion is no longer ensured due to a component defect or power cut the burnback flap in the pellet chute is released This directly interrupts the connection between the pellet container and push in scre...

Страница 15: ...e particular care of your fingers and any panels and stove attachments Select soft bases to prevent scratches to your living space furniture and stove panels Dismantling stone Open the container lid t...

Страница 16: ...nd place them on a clean base Cut the perforated opening in the left rear wall with a hacksaw and deburr the edges with a round file Swap the flue connections and the fluegas cover Grease the fastenin...

Страница 17: ...the outside Insert the handle of the flue gas flap into the stove The handle must then be shifted backwards to close the flap The warning is deleted as soon as the two flaps are activated and the Hom...

Страница 18: ...GRAM PELLET LOG OPERATION X X X door open ON OFF split logs recognised X no split logs recognised X X Stove OFF Ignition Start Control mode Burn off Split log check Split log mode Split log mode Split...

Страница 19: ...MODE the heating times set at the stove can also be activated You can see whether the external demand is currently activated in the INFO main menu in submenu item Info inputs If your stove receives a...

Страница 20: ...fire trough regularly Only clean when cold when embers are extinguished Note To prevent clinker formation it is advisable to operate the stove sometimes on higher power level or according to its comb...

Страница 21: ...event your stove from overheating of the internal components do never cover the convection fins Combustion air intake If necessary please also clean the air intake with a hoover Note Only when the sto...

Страница 22: ...it on a soft clean base Open the fixing bolts of the top cover plate and place it on a soft clean base Open the fixing bolts of the cast cover Turn the cast cover carefully out of the frame and place...

Страница 23: ...ed Cause s pellet log operation Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions pellet log operation Q Wait to end of burning in phase and vent suffi...

Страница 24: ...se are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in...

Страница 25: ...ght Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YES...

Страница 26: ...for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a resul...

Страница 27: ...27 26 EN...

Страница 28: ...e Ofentechnik GmbH is ensuring that its products are eco friendly throughout the product life cycle This is why our commitment for electronic products goes beyond the end of their product life cycle I...

Отзывы: