The technological advances in your new combi stove are the result of 
years of testing and practical experience� The practical advantages 
of your pellet/log stove are convincing:

The range of operating modes leaves nothing to be desired� The 
automatic fuel detection means the operating mode can be changed 
at any time (simply add logs during pellet operation or ignite logs 
with the pellet burner)�

Manually regulated currentless log operation is also possible� This 
ensures faultless operation even in the case of longer power cuts�

Operating comfort

The microprocessor-controlled combustion regulation optimises 
the interaction of flue gas blower, air flap position and screw using 
the current combustion chamber temperature� This guarantees 
optimum combustion and operating status in both pellet and log 
operation�

All function can be regulated centrally using the integrated touch 
display� The intuitive graphic interface permits easy operation; all 
the settings can be made quickly and simply� 

Top efficiency - lowest emissions

A very great heat exchange surface together with optimum 
combustion air control leads to excellent fuel utilisation�

Fine continuous pellet dosing in an optimised burner pot made of 
high-quality grey cast iron leads to virtually complete combustion 
with very good exhaust gas values - and this is guaranteed in every 
operating phase�

The combination of temperature-controlled automatic air regulation 
and optimised wood retainer geometry enable combustion with 
minimum emissions at top efficiency in log operation�

Note

During operation, the flame noise, pellets dropping and actuation 
of the electronic components are audible due to the automatic 
control�

Note

The innovative technology of our combination stove INDUO offers 
you a maximum of heating comfort, depending on the availability 
of the fuel the stove can be heated with pellets and / or logs without 
any modification� 

Both cases are solid fuels that can cause a fogging of the door 
glass during the combustion, particularly with the very fine ash 
from wood pellets� 
By external influences such as chimney draft or pellet quality this 
coating can be very bright or dark black (especially with low power 
)� This is a natural process and is not a shortage� 

We therefore recommend regular cleaning of the door glass, just 
because soot is an excellent insulator and thus the heat dissipation 
can be reduced�

If the stove is heated according to its function in the combined 
operation, a significant improvement can be achieved due to the 
higher temperatures in log wood mode�

Burnback and flue gas flaps

The combi stove safety concept is based on double safeguards� If 
faultless operation is no longer ensured due to a component defect 
or power cut, the burnback flap in the pellet chute is released� This 
directly interrupts the connection between the pellet container 
and push in screw� Thus preventing pellet burnback� Closing the 
burnback flap at the same time opens the flue gas flap thus ensuring 
safe burning off of the fuel in the combustion chamber�

Note

Check with every maintenance / cleaning the correct operation of 
the flue flaps�

Overheating

A safety temperature limiter (STL) switches the stove off 
automatically on overheating� Once the stove has cooled, the STB 
at the stove rear must be unlocked manually (pressed)� The stove is 
ready for operation again after acknowledging the error message 
at the touch display and activating the burnback and flue gas flap 

(see ACTIVATING THE BURNBACK AND FLUE GAS FLAP)

� The 

operating mode set is retained�

Note

Maintenance and cleaning work must be performed if overheating 
occurs! If this error recurs, operation without danger is no longer 
guaranteed; notify customer service immediately�

Low-temperature shutdown

The unit switches off if the stove cools below a minimum temperature� 
This switch-off may occur if pellet ignition is delayed�

Electrical excess current protection

The stove has a main fuse (at the rear) to protect against excess 
current�

Automatic cleaning cycle

The speed of the flue gas fan is increased every hour for a short 
period to blow ash from the burn pot, increasing the operational 
safety� The status indicator CLEANING appears on the display�

Every 5 hours (interval adjustable) an additionally automatic cleaning 
cycle is performed� The stove stops, the automatic cleaning tilts the 
grid and then re-ignites the stove� The status indicator CLEANING 
appears on the display continuously� The cleaning procedure with 
tilting the grid is to convey ash and clinker from the burn pot into 
the ash drawer� 

Note

At runtime of the cleaning cycle occures a noise due to the turning 
grid (stove start or big cleaning)�

Note

This additional function does not replace a manual cleaning 
as described in 

CLEANING

 and 

MAINTENANCE

, as this is 

absolutely necessary to do regularly�

Component monitoring

All the electrical components used are continuously monitored 
during operation� If a component is defective or can no longer be 
actuated correctly, then operation is stopped and a warning or error 
message is issued 

(see MANUAL TOUCH DISPLAY)

Auger motor monitoring

Too long or wet pellets as well as pellets with too high dust content 
(see 

BRIEF INFORMATION ON FUEL PELLETS

) can cause 

so-called “auger jammers” in the auger channel� This may also 
happen if the pellets accumulate in the burn pot and the backlog 
reaches into the chute� The auger motor reacts in both cases with 
an increased current consumption, which causes the error message: 
INSERTION MOTOR JAMMED� The stove will be stopped� Please call 
the customer service immediately�

Содержание induo II

Страница 1: ...INDUO II Operating manual...

Страница 2: ...are pellets 12 Wood pellet specification according to ENplus A1 12 Pellet container refilling during operation 12 Pellet storage 12 5 BRIEF INFORMATION ON COMBUSTIBLE LOGS 13 Suitable fuels and fuel...

Страница 3: ...surfaces 20 12 CLEANING 21 Cleaning the convection air openings 21 Combustion air intake 21 Cleaning the pellet container 21 Bearings 21 Checking door seal 21 Cleaning flue pipes 21 Cleaning flue gas...

Страница 4: ...am 7 8 9 16 15 11 11 11 12 12 13 13 5 5 18 4 4 20 19 17 10 14 14 6 1 1 2 2 3 3 21 66 28 27 29 33 25 34 24 35 32 26 30 31 39 42 37 36 38 22 23 48 47 45 46 50 53 51 52 54 57 67 68 69 55 56 49 64 65 52 5...

Страница 5: ...8 112 107 105 104 103 99 92 94 97 95 110 109 96 108 114 111 93 90 91 102 101 100 106 132 139 141 142 143 135 136 137 135 144 137 145 138 126 127 146 134 133 150 147 123 121 122 128 130 155 154 129 153...

Страница 6: ...rmediate shaft turning grid Nr Art Nr Description 49 N107521 Hexagonal screw M05x12 50 Z34824 Bearing clamping plate metallic Z34965 Bearing clamping plate black 51 N104718 Circlips D08 52 N108310 Sin...

Страница 7: ...Seal for ignition 123 Z34464 Insertion screw 124 B15248 Sensor tube 125 B16676 Flame temperatur sensor 126 L01954 Pressure bracket 127 N111862 Screw motor stepless 128 Z11915 Lock ring conveyer screw...

Страница 8: ...pacity l kg 51 33 Electric supply V Hz 230 50 Average electrical input W 20 Fuse A 2 5 T Pellet Operation Measure Data Heating capacity range kW 3 10 Efficiency in pellet mode 91 CO2 13 3 CO emission...

Страница 9: ...e embers together to form a firebed when you add new fuel logs Q Placing non heat resistant objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Laundry racks et...

Страница 10: ...Phone the fire brigade and get yourself and other residents out of harm s way Note Due to the size of the combustion chamber door it is necessary not to open the door abruptly to prevent the flames c...

Страница 11: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Страница 12: ...with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list of monitored fuel man...

Страница 13: ...particularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all softwoods and tends to spray sparks Wood t...

Страница 14: ...tion is no longer ensured due to a component defect or power cut the burnback flap in the pellet chute is released This directly interrupts the connection between the pellet container and push in scre...

Страница 15: ...e particular care of your fingers and any panels and stove attachments Select soft bases to prevent scratches to your living space furniture and stove panels Dismantling stone Open the container lid t...

Страница 16: ...nd place them on a clean base Cut the perforated opening in the left rear wall with a hacksaw and deburr the edges with a round file Swap the flue connections and the fluegas cover Grease the fastenin...

Страница 17: ...the outside Insert the handle of the flue gas flap into the stove The handle must then be shifted backwards to close the flap The warning is deleted as soon as the two flaps are activated and the Hom...

Страница 18: ...GRAM PELLET LOG OPERATION X X X door open ON OFF split logs recognised X no split logs recognised X X Stove OFF Ignition Start Control mode Burn off Split log check Split log mode Split log mode Split...

Страница 19: ...MODE the heating times set at the stove can also be activated You can see whether the external demand is currently activated in the INFO main menu in submenu item Info inputs If your stove receives a...

Страница 20: ...fire trough regularly Only clean when cold when embers are extinguished Note To prevent clinker formation it is advisable to operate the stove sometimes on higher power level or according to its comb...

Страница 21: ...event your stove from overheating of the internal components do never cover the convection fins Combustion air intake If necessary please also clean the air intake with a hoover Note Only when the sto...

Страница 22: ...it on a soft clean base Open the fixing bolts of the top cover plate and place it on a soft clean base Open the fixing bolts of the cast cover Turn the cast cover carefully out of the frame and place...

Страница 23: ...ed Cause s pellet log operation Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions pellet log operation Q Wait to end of burning in phase and vent suffi...

Страница 24: ...se are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in...

Страница 25: ...ght Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YES...

Страница 26: ...for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a resul...

Страница 27: ...27 26 EN...

Страница 28: ...e Ofentechnik GmbH is ensuring that its products are eco friendly throughout the product life cycle This is why our commitment for electronic products goes beyond the end of their product life cycle I...

Отзывы: