2. IMPORTANT INFORMATION

General warning and safety information

Observance of the introductory general warning information is imperative.

 

Q

Read the entire manual thoroughly before installing and putting the stove into 

service. Observe the national provisions and laws as well as the regulations 

and rules applicable locally.

 

Q

RIKA stoves should only be installed in rooms with normal humidity (dry 

areas according to VDE 0100 Part 200). The furnaces are not splash water 

protected and may not be installed in wet areas.

 

Q

Only approved transport equipment with sufficient load carrying capacity 

may be used with your heating appliance.

 

Q

Your heating appliance is not suitable for use as a ladder or stationary 

scaffolding.

 

Q

The burning of fuel releases heat energy that lead to extensive heating of 

the stove surfaces, doors, door and operating handles, glass, flue pipes 

and possibly the front wall. Refrain from touching these parts without 

appropriate protective clothing or equipment e.g. heat-resistant gloves or 

means of operation (operating handle).

 

Q

Make your children aware of this particular danger and keep them away from 

the stove during heating.

 

Q

Only burn approved heating materials.

 

Q

The combustion or introduction of highly flammable or explosive materials 

such as empty spray cans etc. in the combustion chamber and storing them 

near the stove is strictly prohibited due to the danger of explosion.

 

Q

No light or inflammable clothing is to be worn when post-heating.

 

Q

Use the heat-resistant gloves supplied to open the doors of your stove.

 

Q

Only use suitable tools from our range of accessories when handling embers 

and make sure that no embers fall out of the combustion chamber onto 

inflammable material.

 

Q

Push the embers together to form a firebed when you add new fuel (logs).

 

Q

Placing non-heat resistant objects on the stove or near it is prohibited.

 

Q

Do not place clothing on the stove to dry.

 

Q

Laundry racks etc. must be placed at a sufficient distance to the stove – 

ACUTE DANGER OF FIRE!

 

Q

When your stove is burning, the use of highly inflammable and explosive 

materials in the same or adjacent rooms is prohibited.

Note

Waste and liquids may not be burnt in the stove!

Note

To prevent your stove from overheating of the internal components,

do never cover the convection fins!

Note

Your stove will expand and contract during the heating and cooling phase. 

This can sometimes lead to slight bending or cracking noises. This is normal 

and is no reason for a complaint.

First heating

The stove body, just as various steel parts, cast iron parts and the flue pipes 

are painted with a heat resistant paint. During the first heating the paint dries 

out completely. This may cause a slight smell. Touching or cleaning the painted 

surfaces during the curing should be avoided. The hardening of the paint is 

finished after the first heating with high power. 

Safety distances

Note

1. To non-combustible objects

a > 40 cm, b > 10 cm

2. To combustible objects and reinforced concrete load-bearing walls

a > 80 cm, b > 20 cm

Tip

Please observe a minimum distance of 20 cm behind and sideways the stove 

for maintenance.

Содержание FOX II Rikatronic3

Страница 1: ...FOX II FOX II Operating Manual...

Страница 2: ...GS 11 Suitable fuels and fuel amounts 11 Wood types 11 Output controlling 11 Clean combustion 11 4 INSTALLING THE STOVE 12 General information 12 Connection to the chimney 12 Connecting to a steel chi...

Страница 3: ...ass 18 Checking door seal 18 Cleaning painted surfaces 18 Cleaning the flame temperature sensor 18 Cleaning the convection air openings 18 Combustion air air intake 18 Cleaning the flue gas channels 1...

Страница 4: ...9 Door adjustment plate 65 Z33323 Deflector plate top 66 Z33588 Deflector plate bottom 67 B12322 Door lock 68 1 N111863 Door spring 69 1 Z34342 Wire cable 70 N111860 Allen screw 72 N111798 Cylindrical...

Страница 5: ...exploded diagram A D C A 3 4 7 8 16 17 18 19 20 21 22 23 25 28 34 35 36 39 40 44 45 46 59 65 66 67 70 72 C D 10 5 10 14 15 68 56 69 48 50 64 55 47 55 63 48 19 120 126 119 118 124 122 123 117 121 125...

Страница 6: ...Self locking door exploded diagram E 80 81 82 83 85 86 87 89 90 92 94 96 97 98 99 99 100 101 102 103 104 105 106 107 E...

Страница 7: ...7 EN 6 Spare part overview exploded diagram B B 1 33 32 37 43 53 60 60 6 11 11 12 13 41 42 51 52 13 114 113 116 115...

Страница 8: ...0 242 3 Chimney draft requirement Pa 12 12 only type RIKATRONIC3 The owner of small firing system or the person authorised for the small firing system is to keep the technical documentation and is to...

Страница 9: ...s to be worn when post heating Q Q Use the heat resistant gloves supplied to open the doors of your stove Q Q Only use suitable tools from our range of accessories when handling embers and make sure t...

Страница 10: ...ed with the combustion chamber door closed Q Q The combustion chamber door may only be opened to add fuel and must then be closed again otherwise other firing installations connected to the chimney ma...

Страница 11: ...rticularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all softwoods and tends to spray sparks Wood type...

Страница 12: ...84 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspection and cleaning must be present The flue pipe connection...

Страница 13: ...r for combustion An explosive gas air mixture may arise and cause an eventual heavy deflagration For safety reasons it is recommended to leave the combustion chamber door closed and press the control...

Страница 14: ...d and the display is constantly red open the combustion chamber door and sweep the ashes into the ashtray Place left and right 2 small pieces of chipboard lengthways in the bottom of the combustion ch...

Страница 15: ...ooled down is switched off and that the combustion chamber door is closed Q Q Plug in the mains plug and activate the main switch at the rear of the stove Q Q Wait until the reference run has been com...

Страница 16: ...ermitted The stove must be heated up again The display lamp is constantly GREEN The stove is in normal operation The display lamp is constantly YELLOW The stove is in ECO operation The display lamp fl...

Страница 17: ...e sensor and if required clean the sensor carefully see Cleaning and Maintenance Contact RIKA customer service XX X The display lamp flashes 2x RED and 1x YELLOW The magnetic switch is defective or ja...

Страница 18: ...rt can be removed with a special cleaner free from corrosive acids and solvents otherwise there is a risk of damage to the glass surface available from your stove dealer Usual cleaners containing acid...

Страница 19: ...Refitting the top smoke pipe connection to the rear connection Remove the stone top plate Remove the lamellas by loosening the two hexagon head screws Take off the pre stamped round section in the re...

Страница 20: ...ner Problem 2 Stove smells strongly and or fumes are emitted Cause s Q Q Burning in phase taking into service Q Q Stove has accumulated dust and or dirt Possible solution s Q Q Wait to end of burning...

Страница 21: ...nuals valid at the time of purchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the clai...

Страница 22: ......

Страница 23: ...23 EN 22...

Страница 24: ...alid one Technical and design changes as well as typesetting and printing errors reserved 2019 RIKA Innovative Ofentechnik GmbH Z35861_EN_FoxII_R3 12 07 2019 RIKA Innovative Ofentechnik GmbH M llervie...

Отзывы: