16
Status displays
LED display
Meaning
Action to be taken
The display lamp
flashes intermittently
RED
The stove has just been switched on and the air
flaps start the reference run.
The control system starts a reference run again
after a brief power failure.
The stove cannot heat up until the display lamp
stops flashing.
The display lamp is
constantly
RED
The combustion chamber is cold and the stove is
in neutral.
The combustion chamber temperature has fallen
below the temperature specified for adding wood.
The stove is ready to heat up.
Optimum control process can no longer be
ensured, adding wood is not permitted. The
stove must be heated up again.
The display lamp is
constantly
GREEN
The stove is in normal operation.
The display lamp is
constantly
YELLOW
The stove is in ECO operation.
The display lamp
flashes regularly
RED
The temperature specified for adding wood was not
reached.
Open the combustion chamber door and add a
log or let the stove go out.
The display lamp
flashes regularly
GREEN
After the opening of the combustion chamber door,
the stove tries to light the wood added.
The riddle grate should be open during
combustion as well as a lockable damper clap
in the flue pipe (if in use).
The display lamp
flashes regularly
YELLOW
The ECO key was pressed after adding wood.
The magnetic switch sequence was initiated
See “Actions to be taken – flashes regularly
green”
See “Complete closing of the air flaps”