![Rigol HDO1000 Series Скачать руководство пользователя страница 123](http://html1.mh-extra.com/html/rigol/hdo1000-series/hdo1000-series_user-manual_1461145123.webp)
Trigger Condition
Click or tap the drop-down button of When to select the desired trigger condition.
•
SOF: triggers at the start of a frame.
•
EOF: triggers at the end of a frame.
•
Remote ID: triggers on the specified ID of Remote frame. When you select
Remote ID, you need to set the following parameters.
-
Click or tap the Extended ID on/off switch to enable or disable the
extended ID.
-
Click or tap the input field of Data, and then the "Format" interface is
displayed. You can set the data bit that needs to be operated on. For
details, refer to descriptions in
.
•
Overload: triggers on the overload frames.
•
Frame ID: triggers on the data frames with the specified ID. After you select
Frame ID, you can refer to the "Remote ID" mentioned above to set the
Extended ID and ID.
•
Frame Data: triggers on the data frames with the specified Data. When you
select Frame Data, you need to set the following parameters.
-
Click or tap the input field of Data, and then the "Format" interface is
displayed. You can set the data bit that needs to be operated on. For
details, refer to descriptions in
.
-
Click or tap the input field of Bytes and use the pop-up numeric keypad to
set the value. You can also use the corresponding numeric keypad to set the
value. The range is from 1 to 8.
•
Data & ID: triggers on the data frames with the specified ID and data. When you
select Data & ID, you need to set the ID, Data, and Bytes.
•
Frame Error: triggers on the error frame.
•
Bit Fill: triggers on the error frame with the bit fill.
•
Answer Error: triggers on the answer error frame.
•
Check Error: triggers on the check error frame.
•
Format Error: triggers on the format error frame.
•
Random Error: triggers on the random error frame, such as the format error
frame, answer error frame, etc.
Trigger Mode
In Sweep, select Auto, Normal, or Single as the trigger mode. For details, refer to
.
Triggering the Oscilloscope
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
HDO1000 User Guide
109