This command is invalid when "Ext" modulation source is selected. You can run the
command to set or query the pulse modulation
source.
Return Format
The query returns 1 or 0.
Example
:PULM:OUT:STAT ON /*Enables the pulse output (by default, CH1 is
selected).*/
:PULM:OUT:STAT? /*The query returns 1.*/
3.1.9.3
[:SOURce][:RF]:PULM:PERiod
Syntax
[:SOURce][:RF
<
channel>
]:PULM:PERiod
<
value>
[:SOURce][:RF
<
channel>
]:PULM:PERiod?
Description
Sets the single pulse period for the specified channel.
Queries the single pulse period for the specified channel.
Parameter
Name
Type
Range
Default
<channel>
Discrete
1|2|3|4|5|6|7|8
1
<value>
Real
40 ns to 170 s
500 us
Remarks
•
When <value> is set in "Number" form, the default unit is s. Besides, <value>
can also be set in " Unit" form. For example, 1000ms.
•
The default unit of the return value is s.
•
The period of the single pulse is related to the current "Mode" setting.
•
This command is invalid when "Ext" modulation source is selected or "Train"
pulse is selected. You can run the
command to set
or query the pulse modulation source; run the
command to set or query the pulse type of the pulse modulation.