![Rigol DSG5000 Series Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/rigol/dsg5000-series/dsg5000-series_programming-manual_1460929023.webp)
Example
:CORR:FLAT:LIST? 2,3 /*Queries three lines of flatness correction
data starting from the 2nd line of the flatness correction list
for CH1 (by default, CH1 is selected).*/
3.1.4.4
[:SOURce][:RF]:CORRection:FLATness:DELete
Syntax
[:SOURce][:RF
<
channel>
]:CORRection:FLATness:DELete
<
Row>
Description
Deletes one correction point from the flatness correction list for the specified
channel.
Parameter
Name
Type
Range
Default
<channel>
Discrete
1|2|3|4|5|6|7|8
1
<Row>
Integer
1 to total number of lines in the
current list
-
Remarks
•
<Row> represents the line number in the flatness correction list. The total
number of lines is the total number of correction points in the flatness
correction list.
•
Each correction point corresponds to one frequency value and amplitude value.
•
You can use this command to reduce the number of lines from the list or use
[:SOURce][:RF]:CORRection:FLATness:PAIR
command to increase the number
points in the list.
Return Format
N/A
Example
:CORR:FLAT:DEL 2 /*Deletes the second line from the flatness
correction list for CH1 (by default, CH1 is selected).*/
Command System
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.