To Display a Reference Waveform
Figure 2-34
Reference waveform display
z
Push REF button to show the reference waveform menu.
z
Continue Pressing button No.1 to turn on or turn off one to four reference
channels.
z
Select a REF channel as the current reference channel from the channels
activated by step 2.
z
Continue pressing button No.3 to select a signal source channel from CH1, CH2,
CH3, CH4 and MATH.(If the MATH is not available ,press MATH button to
activate MATH)
z
Turn vertical knob
, multifunctional knob
, vertical knob
to adjust the waveform (derived from step 4) to a suitable position
and expand or express the waveform horizontally to a proper situation.
z
Access page 1 of
REF
menu, Press button No.4 to select the saving location of
REF waveform.
z
Access page 2 of
REF
menu, and then press button No.2 to save the current
waveform on the screen to internal or external memory as a reference
waveform.
NOTE:
The Reference function is not available in X-Y mode.