![Rigol DG2000 Series Скачать руководство пользователя страница 97](http://html1.mh-extra.com/html/rigol/dg2000-series/dg2000-series_user-manual_1461078097.webp)
RIGOL
© 2006 RIGOL Technologies, Inc
User’s Guide for DG2000 Series
2-71
Make sure that the Baud Rate and the Parity match the computer. Besides, make
sure that the RS232 cable is connected correctly. The I/O setting is stored in the
Non-Volatile Memory, and will show when the power is on.
Press Utility
Æ
I/O
Æ
RS232 , enter the following interface.
Figure 2-89 The Setting Interface of Setting RS232
Table 2-32 The Menu Explanations of Setting RS232
Function
Menu
Settings Explanation
Baud
Set the RS232 Baud Rate
Parity
Set the RS232 Parity and the data digit
Baud Rate
Set the RS232 Baud Rate. Make sure that the Baud Rate matches the computer. The
optional rates are: 115k, 57.6k, 38.4k, 19.2k, 9600, 4800, 2400, 1200. The default
setting is 9600. The current setting is stored in the Non-Volatile Memory.
Parity
Set the Parity and the data digit of RS232. Make sure that the parity matches the
computer. The optional settings are: Odd, Even and No Parity. The default setting is
“No Parity”. The current setting is stored in the Non-Volatile Memory.
To Set the System