Tapes geometry measurement system  

 

  

 [Version 1.0]  08

th

  December 2014                                       

 

 

15 

12.  Maintenance 

12.1.  General instructions 

Maintenance  of  the  system  is  carried  out  to  ensure  constant-ready  status  and 

continued availability of its work and to prevent premature failure. Maintenance includes 
preventive measures aimed at identification and elimination of defects and to ensure the 
normal operation while installation and working. It is recommended to conduct the daily, 
weekly and annual maintenance work.

 

12.2.  Safety precautions 

During the installation maintenance security measures outlined in the Paragraph 

1 should be observed.

 

12.3.  Maintenance procedure 

12.3.1. Daily maintenance work  

Daily maintenance includes: 

  visual inspection of the system 

  checking of completeness,  

  checking for any damage of the structural elements, power and instrument 

cables, indicators and connectors, 

  weakening of screw connections and insulation failures, 

  before starting work, it is  necessary to  clean the output micrometer windows 

with a soft dry cloth.

 

12.3.2. Regular maintenance work 

Regular maintenance work includes: 

  cleaning of micrometer windows with a dry soft lint-free cloth from contamina-

tion of dirt. 

12.3.3. Yearly maintenance work 

Authenticated calibration of the micrometers should be made once a year. 

12.4.  Operability test 

It is recommended to conduct the functional test at least once at the beginning or 

during the shift, for what it is necessary to complete full cycle control of the geometrical 
parameters of the control sample (not supplied).  

  

13. 

Warranty policy 

Warranty  assurance  for  the  Tape  measurement  system  -  12  months  from  the 

date of putting in operation; warranty shelf-life - 12 months. 

 

 

Содержание RF089 Series

Страница 1: ...AUTOMATED SYSTEM FOR TAPES GEOMETRY MEASUREMENT RF089 Series...

Страница 2: ...on of the thickness measurement micrometers 10 10 3 2 Thermometers calibration 11 10 4 Settings 11 10 5 Measurement journal 12 11 Intended use 14 11 1 Prepatation for use 14 11 1 1 External inspection...

Страница 3: ...ents EN 61326 1 2006 Electrical Equipment for Measurement Control and Labora tory Use EMC Requirements General requirements 3 Laser safety The micrometers make use LED or c w 660 nm wavelength semicon...

Страница 4: ...FROM SHAFT AND TAPE Figure 2 The tape thickness is calculated as the difference between the position of shad ow borders of the tape and the shaft The position of shadow border of the shaft is con trol...

Страница 5: ...er of temperature control points 3 Measurement range for the tape thickness mm 0 02 20 Accuracy of the thickness measurement um 5 Measurement range for the tape width mm 0 2 20 Accuracy of the width m...

Страница 6: ...ement system Version 1 0 08th December 2014 6 7 Overall and mounting dimensions 7 1 Measurement modules Fig 5 and 6 show the dimensions of measurement modules as well as their instal lation on equipme...

Страница 7: ...sults and store the data Fig 6 shows overall dimensions of the device Figure 6 8 Block diagram Fig 7 shows the block diagram of the system Optical micrometers RF651 are linked via RS485 interface Tem...

Страница 8: ...items The power should be switched off while mounting cable connections 10 Software 10 1 Main functions The software provides receipt and analysis of data from micrometers and temperature sensors with...

Страница 9: ...by the main micrometers see P 5 Shaft_cl position of the shaft surface main micrometers while system calibra tion see P 10 3 Shaft_sp the current position of the shaft surface indicated by subsidiary...

Страница 10: ...emove tapes from the shaft start measurement process by pressing Start open the calibration menu Settings Set etalon Sw State Fig 11 select the numbers of the micrometers to be calibrated numbers 7 15...

Страница 11: ...ph for two different temperatures By pressing the Set button the previous calibration value is over written Figure 12 10 4 Settings All sensors in the system are numbered Index from 1 to 18 where the...

Страница 12: ...journal To view the measurement log enter the Journal menu Fig 13 This menu is intended for viewing the measurements stored on a flash drive in the SQLite database file named keep db Each entry has t...

Страница 13: ...system Version 1 0 08th December 2014 13 Figure 13 Figure 14 NOTE To enter the date and time values are special graphics components shown in Figures 15 and 16 respectively To enter numeric values use...

Страница 14: ...3 Switching the system 11 1 4 Calibrating the system 10 3 2 Calibrate the machine according to the Para graph 10 3 2 Calibration should be held on a weekly basis before the work shifts if the positio...

Страница 15: ...cking of completeness checking for any damage of the structural elements power and instrument cables indicators and connectors weakening of screw connections and insulation failures before starting wo...

Отзывы: