Tapes geometry measurement system  

 

  

 [Version 1.0]  08

th

  December 2014                                       

 

 

11 

 

10.3.2. Thermometers calibration  

  stop the calibration process by pressing 

Stop

 button 

  open the calibration menu

 

Settings > Calibration 

(Fig. 12) 

  choose the number of temperature sensor (

Sensor index 

field

)

 

  direct  the  sensor  to  the  surface  with  stated  temperature,  having  entered  the 

temperature value in 

Temp. 1

 or 

Temp. 2 

field and press 

Set 

button. When the 

operation  is  finished  successfully  the  message 

Calibration  parameter  has 

been  successfully  set 

appears.  Detailed  information  on  temperature  sensors 

can be found in OMEGA OS136-1-MA documentation 

  perform  the  operation  described  in  the  previous  paragraph  for  two  different 

temperatures. By pressing the Set button the previous calibration value is over-
written 

 

Figure 12 

10.4.  Settings 

All  sensors  in  the  system  are  numbered  (Index)  from  1  to  18,  where  the  1-6 

match the sensors 1-6 from width measurement group of sensors, numbers 7-15 in the 
Settings match the sensors 1-9 from width measurement group of sensors and numbers 
16-18 match the three temperature sensors. Indexes T1-T6 indicates the results of indi-
rect thickness measurement.  

To perform the system settings enter the General menu. 

  in  the 

Timeout

  field  the  delay  in  milliseconds  between  successive  cycles  of 

the sensors polling is set 

  to set the tolerances choose the number of the sensor in the 

Index

 field and 

set the upper and   lower limits in the fields 

Upper limit

 and 

Lower limit

 corre-

spondingly 

  to set the production task number use the field 

Task Number 

 

Содержание RF089 Series

Страница 1: ...AUTOMATED SYSTEM FOR TAPES GEOMETRY MEASUREMENT RF089 Series...

Страница 2: ...on of the thickness measurement micrometers 10 10 3 2 Thermometers calibration 11 10 4 Settings 11 10 5 Measurement journal 12 11 Intended use 14 11 1 Prepatation for use 14 11 1 1 External inspection...

Страница 3: ...ents EN 61326 1 2006 Electrical Equipment for Measurement Control and Labora tory Use EMC Requirements General requirements 3 Laser safety The micrometers make use LED or c w 660 nm wavelength semicon...

Страница 4: ...FROM SHAFT AND TAPE Figure 2 The tape thickness is calculated as the difference between the position of shad ow borders of the tape and the shaft The position of shadow border of the shaft is con trol...

Страница 5: ...er of temperature control points 3 Measurement range for the tape thickness mm 0 02 20 Accuracy of the thickness measurement um 5 Measurement range for the tape width mm 0 2 20 Accuracy of the width m...

Страница 6: ...ement system Version 1 0 08th December 2014 6 7 Overall and mounting dimensions 7 1 Measurement modules Fig 5 and 6 show the dimensions of measurement modules as well as their instal lation on equipme...

Страница 7: ...sults and store the data Fig 6 shows overall dimensions of the device Figure 6 8 Block diagram Fig 7 shows the block diagram of the system Optical micrometers RF651 are linked via RS485 interface Tem...

Страница 8: ...items The power should be switched off while mounting cable connections 10 Software 10 1 Main functions The software provides receipt and analysis of data from micrometers and temperature sensors with...

Страница 9: ...by the main micrometers see P 5 Shaft_cl position of the shaft surface main micrometers while system calibra tion see P 10 3 Shaft_sp the current position of the shaft surface indicated by subsidiary...

Страница 10: ...emove tapes from the shaft start measurement process by pressing Start open the calibration menu Settings Set etalon Sw State Fig 11 select the numbers of the micrometers to be calibrated numbers 7 15...

Страница 11: ...ph for two different temperatures By pressing the Set button the previous calibration value is over written Figure 12 10 4 Settings All sensors in the system are numbered Index from 1 to 18 where the...

Страница 12: ...journal To view the measurement log enter the Journal menu Fig 13 This menu is intended for viewing the measurements stored on a flash drive in the SQLite database file named keep db Each entry has t...

Страница 13: ...system Version 1 0 08th December 2014 13 Figure 13 Figure 14 NOTE To enter the date and time values are special graphics components shown in Figures 15 and 16 respectively To enter numeric values use...

Страница 14: ...3 Switching the system 11 1 4 Calibrating the system 10 3 2 Calibrate the machine according to the Para graph 10 3 2 Calibration should be held on a weekly basis before the work shifts if the positio...

Страница 15: ...cking of completeness checking for any damage of the structural elements power and instrument cables indicators and connectors weakening of screw connections and insulation failures before starting wo...

Отзывы: