236
Supplementary explanation:MASK input is a byte.Take VB0 as an example:
VB0
7
6
5
4
3
2
1
0
When 0 bit is equal to 1, LCD will display 0 group.
When 1 bit is equal to 1, LCD will display 1 group.
When 2 bit is equal to 1, LCD will display 2 group.
.
.
.
When 7 bit is equal to 1, LCD will display 7 group.
LCD_EDIT
LCD_EDIT: Binds the PLC variable to the edit state of
the LCD.
l
EN
:
Enable
l
UNIT
:
Edit the number of objects in the page
l
AUTO
:
Whether uses LCD keys to edit.
l
DEPTH
:
The current edit depth of edit object.
l
LOOP
:
LOOP edit.
l
FLASH
:
The edit object is flashing or not.
l
V
:
The current value of edit object.
l
VMIN
:
The minimum value of edit object.
l
VMAX
:
The maximum value of edit object.
Содержание PR-12 Series
Страница 26: ...19 1 xLogic CPU PR 12 Series CPU PR 14 and PR 18 series 1 PR 18 CPU 2 PR E extension...
Страница 27: ...20 PR 24 series...
Страница 47: ...40 5 3 Instruction tree...
Страница 50: ...43 CAN interface PLC supports CAN communication CAN communication will be introduced in the communication block...
Страница 54: ...47 Force table interface When PLC is converted from RUN mode to STOP mode the selected output points will be 1...
Страница 58: ...51 5 3 10 Instructions Instructions will be explained in detail in the instructions section...
Страница 73: ...66 2 Select the PLC model ensure that the PLC model in the software is consistent with the actual PLC model...
Страница 93: ...86 2 Enter the illegal real number Example...
Страница 127: ...120 Example...
Страница 137: ...130 Kc gain TD Differential time Ts Sampling time PVn 1 Last time process variable PVn Process variable...
Страница 139: ...132 Special memory bit SM1 0 Zero result SM1 1 overflow SM1 2 Negative result Example...
Страница 143: ...136 Special memory bit SM1 0 Zero result SM1 1 overflow SM1 2 Negative result SM1 3 The divisor is 0 Example...
Страница 149: ...142 Example...
Страница 152: ...145 Example ATCH instruction only needs to be connected once...
Страница 154: ...147 Example...
Страница 172: ...165 Example Notes Cycle times are set to 100 times At the end of the cycle the value of VW100 is 100...
Страница 175: ...168...
Страница 182: ...175 Example When the value of M0 0 is 1 VB0 moves a bit towards the left and VB10 moves a bit towards the right...
Страница 217: ...210 Example Four arithmetic operation Main program...
Страница 218: ...211 Subroutine...
Страница 252: ...245 10 8 Example of serial port free port communication Program 1...
Страница 254: ...247 10 9 Example of CAN free port...
Страница 256: ...249 10 10 MODBUS communication master program Read multiple hold registers and write multiple hold registers...
Страница 258: ...251 Conversion of Process quantity and set value unit...
Страница 259: ...252 Call a PID command every 0 3 seconds...
Страница 260: ...253 The conversion of output value unit...