233
Analog quantity input extension address table:
Analog quantity output extension address table:
10.4 PLC host address range
Digital input
:
I0.0~I1.7
Digital output
:
Q0.0~Q1.7
Analog
input
:
AIW0~AIW18
Analog
output
:
AQW0~AQW18
10.5 Formula
Digital quantity extension addressing formula
:
Digital input Start Address
=I
(
Extension Address
+1
)
.0
Digital output Start Address
=Q
(
Extension Address
+1
)
.0
Analog quantity extension addressing formula:
Extension
Address
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Start
Address
AIW
20
AIW
30
AIW
40
AIW
50
AIW
60
AIW
70
AIW
80
AIW
90
AIW
100
AIW
110
AIW
120
AIW
130
AIW
140
AIW
150
AIW
160
AIW
170
Extension
Address
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Start
Address
AQW
20
AQW
30
AQW
40
AQW
50
AQW
60
AQW
70
AQW
80
AQW
90
AQW
100
AQW
110
AQW
120
AQW
130
AQW
140
AQW
150
AQW
160
AQW
170
Содержание PR-12 Series
Страница 26: ...19 1 xLogic CPU PR 12 Series CPU PR 14 and PR 18 series 1 PR 18 CPU 2 PR E extension...
Страница 27: ...20 PR 24 series...
Страница 47: ...40 5 3 Instruction tree...
Страница 50: ...43 CAN interface PLC supports CAN communication CAN communication will be introduced in the communication block...
Страница 54: ...47 Force table interface When PLC is converted from RUN mode to STOP mode the selected output points will be 1...
Страница 58: ...51 5 3 10 Instructions Instructions will be explained in detail in the instructions section...
Страница 73: ...66 2 Select the PLC model ensure that the PLC model in the software is consistent with the actual PLC model...
Страница 93: ...86 2 Enter the illegal real number Example...
Страница 127: ...120 Example...
Страница 137: ...130 Kc gain TD Differential time Ts Sampling time PVn 1 Last time process variable PVn Process variable...
Страница 139: ...132 Special memory bit SM1 0 Zero result SM1 1 overflow SM1 2 Negative result Example...
Страница 143: ...136 Special memory bit SM1 0 Zero result SM1 1 overflow SM1 2 Negative result SM1 3 The divisor is 0 Example...
Страница 149: ...142 Example...
Страница 152: ...145 Example ATCH instruction only needs to be connected once...
Страница 154: ...147 Example...
Страница 172: ...165 Example Notes Cycle times are set to 100 times At the end of the cycle the value of VW100 is 100...
Страница 175: ...168...
Страница 182: ...175 Example When the value of M0 0 is 1 VB0 moves a bit towards the left and VB10 moves a bit towards the right...
Страница 217: ...210 Example Four arithmetic operation Main program...
Страница 218: ...211 Subroutine...
Страница 252: ...245 10 8 Example of serial port free port communication Program 1...
Страница 254: ...247 10 9 Example of CAN free port...
Страница 256: ...249 10 10 MODBUS communication master program Read multiple hold registers and write multiple hold registers...
Страница 258: ...251 Conversion of Process quantity and set value unit...
Страница 259: ...252 Call a PID command every 0 3 seconds...
Страница 260: ...253 The conversion of output value unit...