background image

Page 10

7. Initial Operation (see data sheet  D 221)

Warning –> Start-up with pipework

At start-up, severe damage may occur if there is debris in the pipework.
We therefore recommend a vacuum tight inlet filter of 5 micron rating is installed for start-up.
The pump will normally be delivered with the bearing oil reservoirs filled but these should be checked before first start up.  The
correct level is in the middle of the sight glass (I

1

, I

2

, I

3

  pict. 2).

The oil reservoirs will normally be supplied with oil level switches (V

1

, V

2

, V

 pict. 2) which will prevent start up or shut the pump

down, in the event of low level.
The pump should be started and stopped momentarily to check the direction of rotation (see direction arrow O).

NOTE! When handling humid or aggressive gases the pump must be operated before and after the process against
a closed inlet, but with an air bleed into the pump.  This pre and post run operation should be carried out for 20-

30 minutes.
Pre-run should ensure that the pump reaches the appropriate operating temperature so that condensation of the pumped gases
is avoided within the pump chambers.

7.1 Potential risks for operating personnel
Noise Emission: The worst noise levels taking into consideration direction and intensity measured according to DIN 45635 part
3 (as per 3. GSGV), are shown in chapter 9.2. When working permanently in the vicinity of an operating pump, we recommend
wearing ear protection to avoid any damage to hearing.

8. Maintenance

When maintaining these units and having such situations where personnel could be hurt by  moving parts or by
live electrical parts the pump must be isolated by totally disconnecting the electrical supply. It is imperative that

the unit cannot be re-started during the maintenance operation.
Do not work a pump that is at its normal operating temperature as there is a danger from hot parts, hot lubricant or hot
coolant.
8.1 Oil lubrication
8.1.1 Bearing oil:
Please make sure that there is always sufficient bearing oil in
the oil tanks (1,2, 3).
Oil change interval: We recommend that the oil should be
changed completely after 8,000 operating hours or at least
yearly.
The viscosity must correspond to ISO-VG 100 according to
DIN 51 519.
We recommend the following oil brands: Bechem VBL 100,
BP Energol RC 100, Esso rotary oil 100, Mobil vacuum pump
oil heavy, Shell Tellus oil C 100 or Aral Motanol HK 100.
8.1.2 Changing the bearing oil (see D 221))
Oil drain:
LP stage (K

1

), MP stage (K

2

), HP stage (K3).

Oil fill port:
LP stage (H

1

), MP stage (H

2

), LP stage (H3).

The waste oil removal should be done according to
environmental regulations. In case of lubricant

change please empty oil tank totally.
8.2 Flat belt
 (pict. 15)
8.2.1 Maintenance
The flat belts for the drive HP/MP stage (R

1

), MP/LP stage

(R

2

), motor/cooling liquid pump (R

3

) do not require any

maintenance and need not be pretensioned.

8.2.2 Flat belt change interval
We would recommend the changing of the Flat Belt (R

1, 

R

2, 

R

3

)

after 15,000 operating hours.

8.2.3 Disassembly/assembly of flat belts
Drain off coolant!
Loosen the screws and push the drive motor (m) as far back
as possible and put aside. Remove the cover (n) after loosen
the screws. Remove the belt from the drive motor/cooling
water pump (R

3

), remove the belts of the MP / LP stage (R

2

),

remove the belt discs (RS) on MP stage by loosening the
appropriate screws. Take off the HP / MP stage belt (R

1

).

The new belt can be assembled in the reverse order, the new
belts need not be pretensioned after assembly.
For assembly and disassembly a special belt tool is required.

n

m

R

1

RS

R

2

R

3

VWP 160-3 / 250-3

15

R

3

m

n

R

1

RS

R

2

VWP 400-3

Содержание INOVAC VWP 160-3

Страница 1: ...BE 221 2 4 99 Werner Rietschle GmbH Co KG Postfach 1260 79642 SCHOPFHEIM GERMANY 07622 392 0 Fax 07622 392300 E Mail info rietschle com http www rietschle com Rietschle UK Ltd Bellingham Way NEW HYTHE...

Страница 2: ...n 8 6 Coolant 9 6 1 External cooling 9 6 2 Radiator cooling 9 6 2 1 Cooling liquid monitoring 9 7 Initial Operation 10 7 1 Risks for service staff 10 8 Maintenance 10 8 1 Oil lubrication 10 8 1 1 Bear...

Страница 3: ...vel there will be a loss in capacity For further advice please contact your supplier The standard versions may not be used in hazardous areas Special versions with Ex proof motors can be supplied All...

Страница 4: ...mosphere without a backing pump INOVAC is the only known Roots vacuum pump that has been especially designed to provide a solution to this problem The back flow which causes the excess heat generation...

Страница 5: ...ers the compression chamber is sealed from the bearing housing by a labyrinth seal consisting of two piston rings PTFE In addition a shaft sealing ring PTFE running on a hardend pressed on shaft sleev...

Страница 6: ...The by pass valves close when the interstage pressures are lower than the exhaust pressure 3 4 6 Sealing gas The INOVAC is supplied as standard with the facility to pressurise the shaft sealing ring c...

Страница 7: ...250 3 VWP 400 3 9 10 5 Installation 5 1 Mechanical installation see data sheet D 221 5 1 1 Mounting Pumps that have reached operating temperature may have a surface temperature of more than 70 C depe...

Страница 8: ...ll cabling used on starters should be secured with good quality cable clamps We recommend that motor starters should be used that are fitted with a time delayed trip resulting from running beyond the...

Страница 9: ...frost A BP anti frost X 2270 A Glacelf Glysantin Glycoshell AF 405 Veedol Antifreeze The water must be ph neutral The liquids should be well mixed before fill in A simple pouring together is not suff...

Страница 10: ...tive that the unit cannot be re started during the maintenance operation Do not work a pump that is at its normal operating temperature as there is a danger from hot parts hot lubricant or hot coolant...

Страница 11: ...ing and the drive coupling half Remove the intermediate flange on the NP stage MS Removing the MP stage HS is carried out in the same manners as with LP stage Assembly of the stages is in reverse orde...

Страница 12: ...400 3 E220 1 drive and gearbox E220 2 radiator cooling E220 3 fresh external Cooling E220 4 basic unit VWP 160 3 250 3 E221 1 drive and gearbox E221 2 radiator cooling E221 3 resh external Cooling E2...

Отзывы: