3.4 INOVAC individual components
3.4.1 Drive
The INOVAC vacuum pump is driven by a
flanged electric motor,  normally the stand-
ard drive supplied with a basic design is
400/690 V, 50 Hz, IP 54, 1450 rpm, B 5
flange:

- VWP 160-3

7.5 kW

- VWP 250-3

7.5 kW

- VWP 400-3

11 kW

There is no  problem to fit other types of
electric motors, including explosion proof
and increased safety models.

3.4.2 Power transmission (pict. 6)
The HP stage is directly driven by the drive
motor. The LP stage, MP stage and cooling
water pump and fan are driven by anti-
static flat belts from the HP stage.
The drive motor and the stages are con-
nected to the flat belt drive using pin and
rubber bush couplings.
At the VWP 400-3 the cooling water fan are
driven by an own motor.

VWP 160-3 / 250-3

VWP 400-3

6

A-side

B-side

7

3.4.3 Compressor stages (pict. 7)
The three compressor stages of the INOVAC consist of the casing (GGG-40), two end covers (DE fixed bearing, NDE floating
bearing, material GGG-40),  two rotors (GGG-40), the synchronising drive gears, the bearing and the sealing systems. In addition
there are valves in the exhaust side of the MP and HP stages.
The rotors of all three stages are the same length as are the casings of the MP and HP stages.  The casing of the LP stage is
somewhat shorter due to lower heat of compression.
In both end covers the compression chamber is sealed from the bearing housing by a labyrinth seal consisting of two piston rings
(PTFE).  In addition a shaft sealing ring (PTFE) running on a hardend pressed on shaft sleeve prevents bearing oil from entering
the labyrinth seal.  Furthermore it is possible to connect sealing gas between the shaft oil seal and the piston ring labyrinth seal
to prevent any possibility of leakage from the compression chamber to the seal area.
The fixed bearing is a twin deep groove ball bearing and the floating bearing is a single deep grove ball bearing.  Both bearings
are lubricated with oil contained within the bearing housing by means of a splash disc.  On the A-side the discs are attached to
the rotor shaft using spacer rings, and on the B-side they are mounted on the synchronising gear so as to lubricate the gear and
the bearing at the same time.
The synchronisation of the rotors is adjusted by means of a conical clamping arrangement of the helical cut synchronising gears.
The drive end bearing housing is sealed by means of a further sealing ring running on a pressed-on shaft sleeve. The non-drive
end is closed by an bearing cover (GGG-40). The end covers are bolted to the rotor casing and are fitted with a PTFE encapsulated
viton O-ring.
The stages and the connections between them and the by-pass system are designed for a hydraulic test of 10 bar.

MP stage

HP stage
(drive)

LP stage
and cooling
fan

HP stage
(drive)

Cooling circulation pump

LP stage

Cooling circulation
pump

MP stage

Содержание INOVAC VWP 160-3

Страница 1: ...BE 221 2 4 99 Werner Rietschle GmbH Co KG Postfach 1260 79642 SCHOPFHEIM GERMANY 07622 392 0 Fax 07622 392300 E Mail info rietschle com http www rietschle com Rietschle UK Ltd Bellingham Way NEW HYTHE...

Страница 2: ...n 8 6 Coolant 9 6 1 External cooling 9 6 2 Radiator cooling 9 6 2 1 Cooling liquid monitoring 9 7 Initial Operation 10 7 1 Risks for service staff 10 8 Maintenance 10 8 1 Oil lubrication 10 8 1 1 Bear...

Страница 3: ...vel there will be a loss in capacity For further advice please contact your supplier The standard versions may not be used in hazardous areas Special versions with Ex proof motors can be supplied All...

Страница 4: ...mosphere without a backing pump INOVAC is the only known Roots vacuum pump that has been especially designed to provide a solution to this problem The back flow which causes the excess heat generation...

Страница 5: ...ers the compression chamber is sealed from the bearing housing by a labyrinth seal consisting of two piston rings PTFE In addition a shaft sealing ring PTFE running on a hardend pressed on shaft sleev...

Страница 6: ...The by pass valves close when the interstage pressures are lower than the exhaust pressure 3 4 6 Sealing gas The INOVAC is supplied as standard with the facility to pressurise the shaft sealing ring c...

Страница 7: ...250 3 VWP 400 3 9 10 5 Installation 5 1 Mechanical installation see data sheet D 221 5 1 1 Mounting Pumps that have reached operating temperature may have a surface temperature of more than 70 C depe...

Страница 8: ...ll cabling used on starters should be secured with good quality cable clamps We recommend that motor starters should be used that are fitted with a time delayed trip resulting from running beyond the...

Страница 9: ...frost A BP anti frost X 2270 A Glacelf Glysantin Glycoshell AF 405 Veedol Antifreeze The water must be ph neutral The liquids should be well mixed before fill in A simple pouring together is not suff...

Страница 10: ...tive that the unit cannot be re started during the maintenance operation Do not work a pump that is at its normal operating temperature as there is a danger from hot parts hot lubricant or hot coolant...

Страница 11: ...ing and the drive coupling half Remove the intermediate flange on the NP stage MS Removing the MP stage HS is carried out in the same manners as with LP stage Assembly of the stages is in reverse orde...

Страница 12: ...400 3 E220 1 drive and gearbox E220 2 radiator cooling E220 3 fresh external Cooling E220 4 basic unit VWP 160 3 250 3 E221 1 drive and gearbox E221 2 radiator cooling E221 3 resh external Cooling E2...

Отзывы: