17
GENERAL
1
2
4
7
11 12 13
15
14
3
5
8
9
10
6
1
Burner lockout indicator
2 DHW mode selector (for use with remote storage cylinder: accessory)
3 Central heating or room temperature setting key
4 DHW temperature setting key
(for use with remote storage cylinder: accessory)
5 Reset key.
Restores normal functioning after a safety shutdown.
6 Chimney sweep mode selection.
Press and hold keys 3 and 4 (for between 3 and 6 seconds) to enter chimney sweep mode.
7 Parameter selection keys
8 Parameter selection keys
9 Value decrement/increment keys
10 Value decrement/increment keys
11 Info key
12 Display
13 Functioning mode selection button.
A line appears under the symbols:
s
Automatic: the boiler functions according to the set program
o
Daytime: the boiler operates at daytime (comfort) setpoint
l
Night-time: the boiler operates at night-time (reduced) setpoint
b
Stand-by
14 Housing for controller (accessory)
15 Main switch
1 .13
Control panel
CONTROL PANEL AND SYMBOLS