Safety and prevention

20044359

2.1

Introduction

The burners have been designed and built in compliance with
current regulations and directives, applying the known technical
rules of safety and envisaging all the potential danger situations.

It is necessary, however, to bear in mind that the imprudent and
clumsy use of the equipment may lead to situations of death risk
for the user or third parties, as well as the damaging of the burn-
er or other items. Inattention, thoughtlessness and excessive
confidence often cause accidents; the same applies to tiredness
and sleepiness.

It is a good idea to remember the following:

The burner must only be used as expressly described. 
Any other use should be considered improper and therefore
dangerous.
In particular:
it can be applied to boilers operating with water, steam, dia-
thermic oil, and to other users expressly named by the manu-

facturer;
the type and pressure of the fuel, the voltage and frequency of
the electrical power supply, the minimum and maximum deliv-
eries for which the burner has been regulated, the pressurisa-
tion of the combustion chamber, the dimensions of the
combustion chamber and the room temperature must all be
within the values indicated in the instruction manual.

Modification of the burner to alter its performance and destina-
tions is not allowed.

The burner must be used in exemplary technical safety condi-
tions. Any disturbances that could compromise safety must be
quickly eliminated.

Opening or tampering with the burner components is not
allowed, apart from the parts requiring maintenance.

Only those parts envisaged by the manufacturer can be
replaced.

2.2

Personnel training

The user is the person, body or company that has acquired the
machine and intends to use it for the specific purpose. He is re-
sponsible for the machine and for the training of the people
working around it.

The user:

Undertakes to entrust the machine exclusively to suitably
trained and qualified personnel.

Must take all the measures necessary to prevent unauthorised
people gaining access to the machine.

Undertakes to inform his personnel in a suitable way about the
application and observance of the safety instructions. With
that aim, he undertakes to ensure that everyone knows the
use and safety instructions for his own duties.

Must inform the manufacturer if faults or malfunctioning of the
accident prevention systems are noticed, along with any pre-
sumed danger situation.

Personnel must always use the personal protective equipment
envisaged by legislation and follow the indications given in this
manual.

Personnel must follow all the danger and caution indications
shown on the machine.

Personnel must not carry out, on their own initiative, opera-
tions or interventions that are not within their province.

Personnel are obliged to inform their superiors of every prob-
lem or dangerous situation that may arise.

The assembly of parts of other makes, or any modifications,
can alter the characteristics of the machine and hence com-
promise operating safety. The manufacturer therefore
declines any and all responsibility for any damage that may
be caused by the use of non-original parts.

2

Safety and prevention

Содержание RS 28/E

Страница 1: ...20044359 6 06 2015 Installation use and maintenance instructions Forced draught gas burner Progressive two stage or modulating operation CODE MODEL 20044216 RS 28 E 20105015 RS 38 E GB...

Страница 2: ...Original instructions...

Страница 3: ...io LMV37 4 12 3 11 Actuators SQM33 5 15 4 Installation 16 4 1 Notes on safety for the installation 16 4 2 Handling 16 4 3 Preliminary checks 16 4 4 Boiler plate 16 4 5 Blast tube length 17 4 6 Securin...

Страница 4: ...Contents 6 Maintenance 27 6 1 Notes on safety for the maintenance 27 6 2 Opening the burner 28 6 3 Closing the burner 28 A Appendix Spare parts 29 B Appendix Accessories 32 C Appendix Burner start up...

Страница 5: ...nerator is to be installed The instruction manual shows the serial number of the burner the address and telephone number of the nearest Assis tance Centre The system supplier carefully informs the use...

Страница 6: ...manual 1 2 1 Owner s responsibility Please pay attention to the Safety Warnings contained within this instruction manual Keep this manual for your records and provide it to your quali fi ed service a...

Страница 7: ...h the burner components is not allowed apart from the parts requiring maintenance Only those parts envisaged by the manufacturer can be replaced 2 2 Personnel training The user is the person body or c...

Страница 8: ...Low MBtu hr kW 198 58 266 78 Fuel Natural or propane gas Max delivery Pressure at maximum delivery 2 natural gas SCFH WC 1232 2 95 1665 2 6 Operation Low high low or modulating Standard application Bo...

Страница 9: ...remote 25 Fan motor with capacitor 26 Ground terminals 27 Auxiliary fuse 28 Switch OFF ON 29 Signal Power ON 30 Lamp signal Call for heat 31 Signal Ignition ON 32 Signal Fuel ON 33 Burner terminal bo...

Страница 10: ...maximum dimension of the burner when open without casing is give in measurement H Tab D 1 Blast tube short long obtainable with the kit 3 7 Standard equipment Gas train flange No 1 Flange gasket No 1...

Страница 11: ...e effect the expansion of the air volume i e the reduction of air density The burner fan s delivery remains substantially the same but the oxygen content per cubic meter and the fan s head are reduced...

Страница 12: ...respect to the equivalent delivery Qe H1r H1 x Qr Q 2 w c MBtu hr Qe H1 H3 H2 A Fig 5 D2617 Above sea level Average barom pressure CORRECTION FACTOR F Air temperature F C ft m WC mbar 0 0 C 41 5 C 50...

Страница 13: ...ce dimensions The firing rates were set in relation to certified test boilers Fig 6 indicates the diameter and length of the test combustion chamber Example Output 1388 MBtu hr diameter 20 inch length...

Страница 14: ...s via which it is possible to easily identify any causes of malfunctioning Mechanical design The following system components are integrated in the LMV37 4 basic unit Burner control with gas valve prov...

Страница 15: ...oltage Nominal current Power factor AC 120 V 50 60 Hz 1 6 A pilot duty load declaration to UL372 cos 0 4 Alarm output Nominal voltage Nominal current Power factor AC 120 V 50 60 Hz 1 A cos 0 4 Ignitio...

Страница 16: ...T P 10 Shutdown Operation Startup Valve proving OUTPUTS INPUTS Phase number Fuel Actuator 2 Air Actuator 1 Actuators Safety limit thermostat STB Control thermostat or pressurestat R Flame signal FS Ai...

Страница 17: ...s can be seen on the dis play of the Operator Panel Index 0 for fuel actuator index 1 for air actuator Installation notes Always run the high voltage ignition cables separate from the unit and other c...

Страница 18: ...carried out by qualified personnel as indicated in this manual and in compliance with the standards and regulations of the laws in force WARNING The handling operations for the burner can be high ly...

Страница 19: ...on of the blast tube For boilers having a water cooled front the insulation 4 5 Fig 11 is not required unless it is required by the boiler man ufacturer 4 6 Securing the burner to the boiler Secure th...

Страница 20: ...n notch 4 as in Fig 13 In this case the pressure load loss of the combustion head is given by column A Tab G page 20 Diagram Fig 14 shows the ideal settings for the ring 2 Fig 13 If the gas supply pre...

Страница 21: ...afety time range The pilot gas train must be connected to the gas attachment 5 Fig 15 and can enter the burner from the right or left side 4 10 Gas train It must be type approved according to UL Stand...

Страница 22: ...t operation Gas ring 2 Fig 13 adjusted as indicated in diagram Fig 14 Gas pressure at test point 1 Fig 17 3 WC Pressure in combustion chamber 0 8 WC 3 0 8 2 2 WC A maximum output of 990 MBtu hr shown...

Страница 23: ...ts Check that the electrical supply of the burner corresponds to that shown on the identification label and in this manual Do not invert the neutral with the phase in the electrical supply line Any in...

Страница 24: ...e motor is 400V To reset in the case of an intervention of the thermal relay press the button RESET Fig 19 The button STOP Fig 19 opens the NC 95 96 contact and stops the motor To test the thermal rel...

Страница 25: ...mum safe ty i e with gas delivery at the minimum 5 3 Burner firing Having completed the checks indicated in the previous heading the pilot of the burner should fire If the motor starts but the flame d...

Страница 26: ...ombustion value proceed slowly to the decrease of the output by synchronizing the combustion with the two servomotors and storing the dif ferent setting values DANGER Make sure that the lamps or teste...

Страница 27: ...e knob counter clockwise about 20 of the set point and start up the burner again to ensure the set point is correct If the burner locks out again turn the knob counter clockwise a little bit more 5 7...

Страница 28: ...ght the flame s intensity is displayed as a percentage Example 954 0 0 5 9 Final checks with the burner working S8171 P V h min s Fig 31 Open the control limit operation Open the high limit operation...

Страница 29: ...e sensor 1 Fig 33 Combustion head Open the burner and make sure that all components of the com bustion head are in good condition not deformed by the high tem peratures free of impurities from the sur...

Страница 30: ...n head 12 Fig 34 6 3 Closing the burner To close the burner proceed as follows push the burner 13 Fig 34 at approximately 4 from the elec trical board 14 insert the ignition electrode cables and then...

Страница 31: ...Appendix Spare parts 29 20044359 A Appendix Spare parts...

Страница 32: ...CONTROL BOX B 17 20027017 CONTACTOR C 18 20027018 LIGHT SIGNAL 19 20027020 LIGHT SIGNAL 20 3012956 TRANSFORMER B 21 20027021 SWITCH C 22 20008601 SERVOMOTOR B 23 3012993 MOTOR C 24 20027028 SCREW 25 3...

Страница 33: ...ONT PIECE 48 3003799 SQUARE 48 3003801 SQUARE 49 3003805 SHUTTER C 50 3003807 END CONE C 50 3003809 END CONE C 51 20091984 SPACER 52 3003893 TEST POINT 53 3006211 FUSE A 54 20026791 SUPPORT 55 2002703...

Страница 34: ...r to operate on LPG Gas train according to UL Standards B Appendix Accessories Burner MBtu hr Code RS 28 E 358 1232 3010270 RS 38 E 437 1665 3010271 WARNING The installer is responsible for the supply...

Страница 35: ...Fire High Fire Control Power Supply CO Low Fire High Fire Burner Firing Rate NOX Low Fire High Fire Manifold Pressure Net Stack Temp Low Fire High Fire Pilot Flame Signal Comb Efficiency Low Fire High...

Страница 36: ...URNERS NORTH AMERICA 35 Pond Park Road http www riello ca 2165 Meadowpine Blvd Hingham Massachusetts Mississauga Ontario U S A 02043 1 800 4 RIELLO Canada L5N 6H6 RIELLO S p A I 37045 Legnago VR Tel 3...

Отзывы: