Electrical wiring
20151139
22
GB
7.3
Wiring diagram
Safety thermostat
Limit thermostat
T6A
Burner-earth
Capacitor
Motor
Valve
Ignition
electrodes
N L
Main switch
PE
Blue
White
Black
Flame sensor
Fig. 19
CONTROL BOX
20139680
CAUTION
If the cover is still present, remove it and proceed
with the electrical wiring according to the wiring di-
agrams.
Use flexible cables in compliance with the EN 60
335-1 standard.
WARNING
Test the burner by checking the shutdown of the
burner by opening the thermostats and the lockout
by darkening the flame sensor.
DANGER
Do not swap neutral and phase over,. Follow
the diagram carefully and make a good earth
connection.
The section of the conductors must be at
least 1mm
2
. (Unless requested otherwise by
local standards and legislation).
The electrical wiring carried out by the
installer must be in compliance with the rules
in force in the country.
Содержание RDB 3.2 BX 32/50
Страница 2: ...Istruzioni originali Translation of the original instructions...
Страница 55: ......