9
20158125
GB
Technical description of the burner
4.1
Models available
Tab. A
4.2
Technical data
(1)
Reference conditions: Ambient temperature 20°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(Hi = 11.86 kWh/kg).
Tab. B
4.3
Burner description
1
Reset button with lock-out lamp
2 Flame
sensor
3 Snorkel
(BF)
4 Blast
tube
5 Control
box
6
Pump pressure adjustment screw
7 Pressure
gauge
port
8 Pump
9 Flange
10 Air damper adjustment screw
4
Technical description of the burner
Designation
Voltage
Code
RDB 3.2 BT 58/70
1/230V/50Hz
20157841
Model
RDB 3.2 BT 58/70
Delivery
(1)
Output range
(1)
Output power
(1)
kg/h
kW
kW
4.9 - 5.9
58 - 70
58
Fuel
Kerosene, viscosity 1.6 – 6 mm
2
/s at 20 °C
Electrical supply
Single phase, ~ 50Hz 230 V ± 10%
Motor
rpm
rad/s
W
A
2750
288
150
1.3
Capacitor
F
5
Ignition transformer
Secondary 8 kV – 25 mA
Pump
Kerosene, maximum pressure 10 bar (145 psi)
Absorbed electrical power
kW
0.24
Fig. 1
8
D4266
9
3
10
5
1
6
7
4
2
Содержание RDB 3.2 BT 58/70