FASTECH KI - KIS
8
C.T.R.
FUNCTION
Unblock function
To restore operation, turn the function selector to OFF, wait 5-6
seconds and then set the function selector to the required position.
The boiler restarts automatically.
NOTE:
if the unblock attempts do not restart the boiler, contact the
Technical Support Centre.
4.3
UNBLOCK
FUNCTION
Checks during and after commissioning
After commissioning, ensure that the
FASTECH
boiler runs the start-up
and subsequent shutdown procedure correctly using the:
- function selector
- calibration of the heating water temperature selector and DHW
temperature selector
- required room temperature (adjusting the room thermostat or timer).
Check operation in DHW mode by opening a hot water tap with the
function selector set to Summer mode and to Winter mode.
Check that the boiler stops completely when turning the main system
switch to “OFF”.
Operate the appliance continuously for a few minutes by turning the
main switch to “ON”, setting the function selector to Summer and
keeping the DHW utility tap on. The processing binders and residue
evaporate and the following can be checked:
- supply gas pressure
- combustion.
Supply gas pressure check
- Turn the main system switch to “OFF”.
- Unscrew the case screws (
A
).
A
A
FASTECH KI
FASTECH KIS
- Move the bottom of the case forward and then upwards to detach
it from the frame.
- Unscrew the panel screws (
B
).
- Turn the control panel forwards.
FASTECH KIS
FASTECH KI
B
B
- Unscrew the tapping point screw upstream of the gas valve by
approximately two turns and connect a pressure gauge.
On the control panel:
- set the function selector to
“Summer mode” and the DHW
temperature selector to the maximum
- turn the boiler on by setting the main switch to “ON”
-
open the hot water cock to the maximum flow rate
- with the burner lit at the maximum output, check that the gas
pressure is between the minimum and the nominal supply values
as specified in the multigas table
- turn off the hot water tap
- disconnect the pressure gauge and tighten the pressure tapping
point upstream of the gas valve.
Pressure tapping
point upstream
of valve