47
SHUTDOWN
47
APPENDIX
Error no. Error
Description
Checks
Solutions
37
FLUE_PRESSURE_LOCKING
Flue pressure switch is
closed for the fourth time.
a- Check for obstruction in
the flue piping.
b- Blocking errors should be
recorded prior to the locking
error to occur.
c- Check for condensate in
the hose towards the flue
pressure switch to ensure it
isn’t blocked.
BLOCKING ERRORS
Error no. Error
Description
Checks
Solutions
100
WD_ERROR_RAM
Internal software error
Replace the power control
board
101
WD_ERROR_ROM
Internal software error
Replace the power control
board
102
WD_ERROR_STACK
Internal software error
Replace the power control
board
103
WD_ERROR_REGISTER
Internal software error
Replace the power control
board
104
HIGH_LIMIT_FAIL
Physical high limit test failed
Replace the power control
board
105
HIGH_TEMP_ERROR
Supply temperature exceeds
110°C (230°F) with gas valve
closed
a- Check all hydraulic valves
and pumps are open and
functioning correctly.
b- Check supply sensor.
c- Check the value of the
reading of this sensor in the
info screen.
a- Change the pump or
restart it;
b- Open the valves on
hydraulic circuit;
c- Verify that the
temperature sensor has the
correct resistance values. If
values are incorrect sensor
must be replaced.
106
REFHI_TOO_HIGH
Internal software error
Replace the power control
board
107
REFHI_TOO_LOW
Internal software error
Replace the power control
board
108
REFLO_TOO_HIGH
Internal software error
Replace the power control
board
109
REFLO_TOO_LOW
Internal software error
Replace the power control
board
110
REFHI2_TOO_HIGH
Internal software error
Replace the power control
board
111
REFHI2_TOO_LOW
Internal software error
Replace the power control
board
112
REFLO2_TOO_HIGH
Internal software error
Replace the power control
board
113
REFLO2_TOO_LOW
Internal software error
Replace the power control
board
114
FALSE_FLAME
Flame is detected in a state
in which no flame is allowed