2126
9
GB
LIGHT OIL OPERATION
To get access to the nozzle or adjust the electrodes, loosen the two screws
(A)
and remove the dif-
fuser disc from the cup.
ELECTRODE SETTING
COMBUSTION ADJUSTMENT
The type of nozzle and the pump pressure must be selected on the basis of the desired flow rate.
Nozzle
Pump
pressure
Burner
output
GPH
Angle
bar
kg/h ± 4%
0.75
60°
12
3.2
0.85
60°
12
3.6
1.00
60°
12
4.3
1.25
60°
12
5.3
1.50
60°
12
6.4
1.75
60°
12
7.5
2.00
60°
12
8.5
Diffuser disc
Cup
A
D5839
3
mm
2.5
±
0.3 mm
D5838
NOZZLES RECOMMENDED:
Monarch type R
Delavan type B
Steinen type S
Danfoss type S
PUMP PRESSURE
12 bar:
the pump leaves the fac-
tory set at this value.
14 bar:
Only with a 45º spray
angle and long combus-