Technical description of the burner
3.7
Firing rates
The
MAXIMUM OUTPUT
must be selected within area A.(Fig. 2).
The
MINIMUM OUTPUT
must not be lower than the minimum
limit of the diagram:
600 kW
3.8
Test boiler
The burner/boiler combination does not pose any problems if the
boiler is EC approved and its combustion chamber dimensions
are similar to those indicated in the diagram (Fig. 3).
If the burner must be combined with a boiler that has not been EC
approved and/or its combustion chamber dimensions are clearly
smaller than those indicated in the diagram, consult the
manufacturer.
The firing rates were obtained in special test boilers, according to
EN 676 standard.
In Fig. 3 you can see the diameter and length of the test
combustion chamber.
Example:
Output 650 Mcal/h - diameter 60 cm - length 2 m
ATTENTION
The firing rate value (Fig. 2) has been obtained
considering an ambient temperature of 20 °C, an
atmospheric pressure of 1013 mbar (approx. 0 m
a.s.l.), and with the combustion head adjusted as
shown on page 18.
Fig. 2
Pressure in the chamber
pr
es
su
re
-
mb
ar
Thermal power
- 2
Mcal / h
kW
0
2
4
6
8
10
500 700 900 1100 1300 1500 1700 1900 2100
600 800
1200
1000
2000
1800
1600
1400
2400
2200
11
12
2600 2800
2300 2500
13
14
15
16
17
18
A
D3807
Fig. 3
D715
Co
mbustion chamber
m
Содержание 20190698
Страница 2: ...Translation of the original instructions...
Страница 40: ...20190798 38 GB Appendix Electrical panel layout 0 0 1 1 2 34 5 6 7 8 5 1 9 7 6 8 7 7 7 7 6 6 0 1 0...
Страница 43: ......