8
Attention!
The product has
230 Vac
contacts on the
electronic card.
In conformity with the electrical safety standards it is
forbidden to connect binding posts
3, 4
and
5
directly to a
circuit that receives power greater than
30 Vac/dc
.
• After having installed the device, and
before powering
up the programmer
, release the gates (manual release
mechanism) and move them manually, checking that they
moves smoothly and have no unusual points of resistance.
• Connecting devices to the controlled output contact between
binding posts
6
and
7
also allows you to carry out the autotest
function (enabled using
DIPs 9
and
10
) and check that the
safety devices are functioning correctly.
• Before connecting the appliance make sure that the voltage
and frequency rated on the data plate conform to those of
the mains supply.
• An all pole trip switch with at least
3 mm
between the
contacts must be installed between the unit and the mains
supply.
• Don't use cables with aluminium conductors; don't solder
the ends of cables which are to be inserted into the binding
posts; use cables marked
T min 85°C
and resistant to
atmospheric agents.
• The terminal wires must be positioned in such a way that
both the wire and the insulating sheath are tightly fastened
(a plastic jubilee clip is sufficient).
POWER SUPPLY CONNECTION 230 Vac
• Connect the control and security device wires.
• Run the
230 Vac
mains power supply to the programmer and
connect it to binding posts
42
,
43
and
44
.
L
= live
N
= neutral
= earth
• Connect motor
M1
(the one that will open first) to binding posts:
- 41
= Opening;
- 42
= Closing;
- 43
= Common.
• Connect motor
M2
to binding posts:
- 36
= Opening;
- 37
= Closing;
- 38
= Common.
• These instructions are aimed at professionally qualified "
installers
of electrical equipment
" and must respect the local standards
and regulations in force.
All materials used must be approved and must suit the environ-
ment in which the installation is situated.
• This product and all its relative components has been designed
and manufactured by Cardin Elettronica who have verified that
the product conforms in every aspect to the safety standards in
force.
• Any non authorised modifications are to be considered improper
dangerous and the complete responsibility of the installer.
• This appliance must be used exclusively for the purpose for which
it has been made "
i.e. for the command and control of 230V
Cardin motors
".
• The manufacturer accepts no liability for situations arising from
the use of an electrical installation which does not conform to the
local standards and regulations in force.
Attention!
Only for EU customers -
WEEE marking
.
This symbol indicates that once the products life-span
has expired it must be disposed of separately from
other rubbish. The user is therefore obliged to either
take the product to a suitable differential collection site
for electronic and electrical goods or to send it back to
the manufacturer if the intention is to replace it with a
new equivalent version of the same product.
Suitable differential collection, environmental friendly treatment
and disposal contributes to avoiding negative effects on the
ambient and consequently health as well as favouring the recy-
cling of materials. Illicitly disposing of this product by the owner
is punishable by law and will be dealt with according to the laws
and standards of the individual member nation.
Caution!
mechanical stop anti-derailment buffers must
be installed.
To assembly the box read the instruction manual ZVL365.01 supplied
with the electronic programmer.
Electronic programmer for single/double leaf gates, sliding, hinged or
garage doors running off
230 Vac
.
Digital work time control separately memorised for each gate leaf
guided by a 6-digit display. Possible operation without mechanical
travel limits.
Torque setting. Maximum power initial thrust control, torque limita-
tion and deceleration management with deceleration zone control.
The appliance is fitted with an interface for the insertion of a standard
Cardin radio receiver card.
Suitable for the control of automatic gates and doors with two 230V
motors.The motor rotation speed is electronically controlled, starting
slowly and increasing in speed; the speed is reduced as it nears the
travel limit so as to enable a controlled smooth stop.
Programming is carried out using one button and allows you to set
the entire travel distance of the gates.
IMPORTANT REMARKS
IMPORTANT REMARKS
IMPORTANT REMARKS
READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION.
PAY PARTICULAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
NOT
READING THESE IMPORTANT INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING
ORDER OF THE SYSTEM AND CREATE DANGER SITUATIONS FOR THE USERS OF THE SYSTEM.
USER INSTRUCTIONS
IMPORTANT REMARKS
ELECTRONIC PROGRAMMER
M2
OPEN
C.
CLOSE
CMN
32 33
35
36
37
38 39
40
41 42
43
34
44
45
46
LC 230V~
L
N
230V~
M1
OPEN
C.
CLOSE
CMN
LP 230V~