- 22 -
Inputs zones
Main board has a total of 4 zone inputs (L1 – L4) for Lucky 4 and 8 zone inputs (L1 – L8) for Lucky8,
1 dedicated input for tamper protection (TT). A supplying output V Linee is available, protected by a fuse
of 0,63 A. F3
Zones from 1 to 4 for Lucky 4 and from 1 to 8 for Lucky 8:
Zones of alarm input of control panel, balanced or normally closed according to position of Dip-switch 5.
The connection scheme in the picture is with Dip 5 in ON, thus with balanced input zones; With Dip 5 in
OFF do not use the balance resistances (with the exception of zones 4 and 5 which, if used with “switch
alarm” function must always be balanced).
Zones configuration can be as follows:
Zone 1: immediate or anti-tamper/fire
Zones 2 and 3: immediate or delayed
Zone 4 immediate or “switch alarm”
Zone 5: immediate or “switch alarm” (not available on Lucky 4)
Zones 6,7 and 8: immediate (not available on Lucky 8)
Tamper Zone: input which must always be balanced, no matter the
position of Dip switch 5
With lines set as balanced, the end-line resistances have to be 4.700
ohm and the colours are:
1) Yellow
value 4
2) Violet
value 7
3) Red
number of zeros: 2
4) Gold
tolerance 5%
Zones 4 and 5, whether used in addition to “switch alarm”, have to be necessarily balanced
with end-line resistance.
-
-
-
L1 L2
L3
L5
L7
L4
L6
L8 T T
LINEE
TAMPER
Control Panel Board
ON
1 2 3 4 5 6 7 8
P
2
4
H
F
IR
E
B
A
T
U
A
O
O
C
1
+
+
+
DA
-
-
-
-
DB
L1 L2
L3
L5
L7
L4
L6
L8 T T
-
-
AO AH B
+
S
+
SA C NCNO
-
-
+
IN ALIM.
+
-
S1
S2
1
2
3
4
P1
P2
USCITE
A
STATO
F1
F 2A
F2
F 3.15A
F3
T 0.63 A
B
A
T
T
E
R
IA
RS 485
LINEE
TAMPER VLINEE
VPOT
ALLARME
LUCKY 8
In Lucky 4 the terminals of zones 5,6,7 and 8 are not available
E
N
G