2322
1
GB
INDEX
1.
BURNER DESCRIPTION
1.1
BURNER EQUIPMENT
Flange with insulating gasket . . . No. 1
Screw and nuts for flange to be fixed to boiler . . . . No. 4
Screw and nuts for flange . . . . . . No. 1
Flexible oil pipes with nipples . . . . . . . . . . . . . . . . No. 2
4 pin plug . . . . . . . . . . . . . . . . . . No. 1
1.
BURNER DESCRIPTION . . . . . . . . . . . . . 1
1.1
Burner equipment . . . . . . . . . . . . . . . . . . 1
2.
TECHNICAL DATA . . . . . . . . . . . . . . . . . 2
2.1
Technical data . . . . . . . . . . . . . . . . . . . . . 2
2.2
Overall dimensions. . . . . . . . . . . . . . . . . . 2
2.3
Working field . . . . . . . . . . . . . . . . . . . . . . 2
3.
INSTALLATION . . . . . . . . . . . . . . . . . . . . 3
3.1
Boiler fixing . . . . . . . . . . . . . . . . . . . . . . . 3
3.2
Fuel supply . . . . . . . . . . . . . . . . . . . . . . . 3
3.3
Hydraulic systems . . . . . . . . . . . . . . . . . . 4
3.4
Electrical wiring . . . . . . . . . . . . . . . . . . . . 5
4.
WORKING . . . . . . . . . . . . . . . . . . . . . . . 6
4.1
Combustion adjustment. . . . . . . . . . . . . . 6
4.2
Electrodes adjustment. . . . . . . . . . . . . . . 7
4.3
Pump pressure and air output . . . . . . . . . 8
4.4
Flame detector adjustment . . . . . . . . . . . 8
4.5
Burner start-up cycle . . . . . . . . . . . . . . . . 9
5.
MAINTENANCE . . . . . . . . . . . . . . . . . . . 9
6.
FAULTS / SOLUTIONS . . . . . . . . . . . . . . 10
1 – Pump with pressure reducer
2 – Electronic start delaying
device
3 – Control-box
4 – Reset button with lock-out
lamp
5 – Flange with insulating
gasket
6 – 2nd stage air damper
adjustment assembly
7 – Nozzle holder assembly
8 – Flame detector
9 – Hydraulic jack
10 – 4 pole socket
11 – 2nd stage valve
12 – 1st stage valve
■
BUWAL approval No. 197012.
■
CE Certification No.: 0036 0269/99 as 92/42/EEC.
■
The burner meets protection level of IP 40, EN 60529.
■
Burner with CE marking in conformity with EEC directives: EMC 89/336/EEC, Low Voltage 73/23/EEC,
Machines 98/37/EEC and Efficiency 92/42/EEC.
Fig. 1
S7157
5
6
7
8
9
4
3
2
1
12
11
10
Two stage light oil burner with low pollutant emissions (Nitric Oxide NOx, Carbon monoxide CO and unburnt
Hydrocarbons).
The dimension of the boiler’s combustion chamber must respond to specific
values, in order to guarantee a combustion with the lowest polluting
emissions rate.
The RIELLO Technical Service Personnel will be glad to give
you all the imformation for a correct matching of this
burner to the boiler.