Operating Instructions

 

WARNING

Always wear eye protection to protect your eyes 

against dirt and other foreign objects. 

When inspecting drains that might contain hazard-

ous chemicals or bacteria, wear appropriate pro-

tective equipment, such as latex gloves, goggles, 
face shields, and respirators to prevent burns and 
infections. 

Do not operate this equipment if operator or ma-

chine is standing in water. Operating the machine 
while in water increases the risk of electrical 
shock. Rubber soled, non-slip shoes can help pre-
vent slipping and electric shock, especially on wet 
surfaces.

Perform the following to reduce the risk of injury 

from electrical shock and other causes:

1. Make sure all equipment is properly set up.

2. Pull several feet of push cable from the nanoReel.

Make sure the camera window is clean. In some
cases, placing a slight film of detergent on the
window can minimize debris sticking to the window. 
Place the camera unit into the line to be inspected.

3. Turn the CCU ON. Adjust the camera head LED

lighting brightness and the display image as
specified by the CCU operator’s manual. Make
adjustments to the brightness as necessary.

For instance, white PVC pipe requires less light
than black PVC. Slight adjustments in lighting

brightness can highlight issues discovered during
an inspection. Always use the least amount of
lighting to maximize picture quality and reduce
heat buildup.

4. To record the inspection, follow the instructions in

the specific CCU operator’s manual.

5.  If possible, run water through the system during the

inspection to help keep the system clean, to make
pushing the push cable easier, and to help orient
the image at the bottom of the pipe. This can be
done by placing a hose down the line or turning
on a fixture (for example: flushing a toilet). Shut off
water flow as needed for viewing.

6. Grip the push cable and carefully feed it into the

drain to be inspected. Use rubber gripper type
gloves to manipulate the push cable to improve
grip and to help keep hands clean.

NOTICE 

Use of the nanoReel camera in porcelain ap-

pliances scratch the surface finish of the porcelain. To 
avoid scratching, use a curved non-marking pipe segment 
(such as PVC or ABS pipe) to lead the camera past the por-
celain bowl and into the drain. See the “Using Guide Tubes” 
section in this Operator’s Manual for more information. 

Figure 14  –  Performing an Inspection

When pushing the push cable in to the line, keep the 

push cable clear of any sharp edges on the inlet that 

could cut, grab, or damage the push cable. Grasp and 

push short sections of push cable at a time and keep 

your hands near the inlet to better control the push cable 
and to prevent it from folding over, snapping, cutting or 
otherwise damaging the push cable jacket. Cutting the 

push cable jacket could increase the risk of electrical 
shock. 

When feeding the push cable into the line, watch the 

monitor to see what is coming. When the lights are set at 
less than maximum setting, it may help to occasionally 
turn the brightness up to see what is coming further 
down the line. 

Be aware of obstructions (such as crushed pipe) or 
excessive hard build up in the line that could prevent 
retrieval of the camera. Do not try to use the camera 
head to clear obstructions. The nanoReel is a diagnostic 
tool, not a drain cleaner. Using the camera head to clear 
obstructions could damage the camera head or cause it 
to be caught in the obstruction, preventing removal. 

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Содержание SeeSnake NanoReel

Страница 1: ...lure to under stand and follow the con tents of this manual may result in electrical shock fire and or serious person al injury Operator s Manual Record product serial number below as it appears on th...

Страница 2: ...Legend 6 Assembly 7 Camera Head Routing 7 Installing System Cable 7 Reversing Installing the Display Cradle micro CA 300 inspection Camera 8 Connecting the micro CA 300 Inspection Camera to the nanoR...

Страница 3: ...ective equipment Always wear eye protection The appropriate use of protective equipment such as a dust mask non skid safety shoes a hard hat and hearing protection will reduce personal injuries t Do n...

Страница 4: ...ead these precautions carefully before using the nanoReel to reduce the risk of electrical shock fire or other serious personal injury SAVE ALL WARNINGS AND INSTRUCTIONS FOR FUTURE REFERENCE Keep this...

Страница 5: ...mera inspection through pipes with very small diameters P traps and very small radius bends which conventional inspection systems often cannot inspect When using the nanoReel with an appropriate SeeSn...

Страница 6: ...ch Camera Head Figure 2 Inside Case Figure 3 Rear View with the micro CA 300 inspection camera Icon Legend Table 2 micro CA 300 Icons Icon Meaning Return Key Shutter Key Select Key Arrow Keys Power Ke...

Страница 7: ...head in the provided clip See Figure 6 6 Close and relatch the case Figure 5 Routing the Camera Head Figure 6 Camera Head Properly Routed Installing System Cable NOTICE Do not touch the contact pins...

Страница 8: ...the friction fit at the bottom of the hole 4 Unthread the screw Repeat for each of the remaining three nuts 5 Position the cord wrap arm and cradle on the same side of the case facing in the opposite...

Страница 9: ...two halves around the camera head with their screw holes aligned 3 Fasten the two halves together with the two screws provided Do not over tighten Pre Operation Inspection WARNING Before each use ins...

Страница 10: ...sleeve and match the System Cable plug to the matching SeeSnake System Connector on the CCU See Item 1 Figure 13 2 To join the connectors align the guide pin to the guide socket push the connector str...

Страница 11: ...ent the image at the bottom of the pipe This can be done by placing a hose down the line or turning on a fixture for example flushing a toilet Shut off water flow as needed for viewing 6 Grip the push...

Страница 12: ...d stress the push cable Figure 16 Avoid Pulling at Sharp Angles When inspecting the line try moving the camera head past the area to be inspected and slowly pull it back for better results Pulling the...

Страница 13: ...location precisely For detailed instructions on Sonde locating consult the operator s manual for the locator model you are using Figure 20 Locating the nanoReel Sonde Retrieving the Camera After comp...

Страница 14: ...to function with the nanoReel Other accessories suitable for use with other tools may become haz ardous when used with the nanoReel To reduce the risk of serious injury only use accessories spe cific...

Страница 15: ...t and its implementation into national legislation electrical equipment that is no longer usable must be collected separately and disposed of in an environmentally correct manner Table 3 Troubleshooti...

Страница 16: ...Printed in U S A 1 5HY www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30...

Отзывы: