20 – English
High Output Mode
Higher output settings produce a stronger signal for the
receiver, but reduces battery life. Only use 1,000 mA
High Output Mode if using an 18 V Li-Ion rechargeable
battery, external power, or high capacity NiMH D-cell bat-
teries. Do not use the ST-33Q+ in high output mode with
standard alkaline batteries.
Under normal operating conditions, the output in Direct
Connect Mode is limited to 400 mA to extend battery life.
The current can be adjusted to operate the ST-33Q+ in
high output mode by using the Up and Down Arrow keys
to toggle between
and
.
In Direct Connect Mode the ST-33Q+ displays a current
indicator bar. Hollow boxes represent selected output
current. Solid boxes represent actual output current lev-
els.
If the display screen shows “Lo,” the circuit is open or
the unit is unable to draw adequate current for locating.
Check your connections and improve the circuit to accu-
rately locate.
Inductive Clamp Mode
Read the Operator’s Manual for the Inductive Clamp be-
fore using it with the ST-33Q+. It includes important safe-
ty information and operating instructions.
Use the ST-33Q+ with an inductive clamp by following
these steps:
1. Before connecting the inductive clamp, confirm
that the target conductor is not live and that the ST-
33Q+ is powered off. The ST-33Q+ is not designed
to be connected to live conductors.
2. Insert the inductive clamp plug into the jack on the
ST-33Q+ below the keypad.