English – 17
Direct Connect Mode and Inductive Mode
To remotely set the transmitter to direct connect mode or
inductive mode using the receiver, open the transmitter
control screen. Press the Select key to toggle between
direct connect mode and inductive mode.
Clamp Mode
The receiver can see the transmitter’s clamp mode but
cannot turn the transmitter’s clamp mode on or off. An in-
ductive clampmust be connected to access clamp mode.
Refer to the operator’s manual for your transmitter and
inductive clamp for more information on using inductive
clamp mode.
Output Power
Higher output settings produce a stronger signal for the
receiver, but reduces battery life for the transmitter. Only
use 1,000 mA High Output Mode if using an 18 V Li-
Ion rechargeable battery, external power, or high capaci-
ty NiMH D-cell batteries. Do not use the ST-33Q+ in high
output mode with standard alkaline batteries.
You can read the transmitter’s output power or change it
remotely from the receiver. To remotely change the trans-
mitter’s output power using the receiver, open the trans-
mitter control screen. Press the receiver’s Up and Down
Arrow keys
to adjust the output power.