RICOH SC-10 SERIES
Socket Mode Function Operating Instructions Ver.1.0.0
22/66
Work ID execution request
Message ID
Message name
Description
0x00000005
Work ID execution request
Start work ID execution from the other device.
When "RUN" is set for OUT0 of the external
IO, the state transitions to the ON state.
The rise and fall times are defined by the
user.
Message format
Address
bit
31
16
15
0
0x0000
Message ID
0x0004
Device ID
0x0008
Device name
0x0048
Work ID
0x0088
Work instruction list
0x00c8
Work item
0x0108
Worker ID
0x0148
Work number
0x0188
Checksum value
reserve
Address
Size
Attribute
Field name
Description
0x0000
4 byte
uint32
Message ID
Message unique ID
0x0004
4 byte
uint32
Device ID
Set the lower 4 bytes of the MAC address
of the SC-10A.
0x0008 - 0x0047
64 byte
char
Device name
Up to 50 half-width alphanumeric
characters long
0x0048 - 0x0087
64 byte
char
Work ID
Up to 50 half-width alphanumeric
characters long
0x0088 - 0x00c7
64 byte
char
Work instruction
list
Up to 50 half-width alphanumeric
characters long
0x00c8 - 0x0107
64 byte
char
Work item
Up to 50 half-width alphanumeric
characters long
0x0108 - 0x0147
64 byte
char
Worker ID
Up to 50 half-width alphanumeric
characters long
0x0148 - 0x0187
64 byte
char
Work number
Up to 50 half-width alphanumeric
characters long
0x0188
2 byte
uint16
Checksum value
Set the lower 2 bytes in the sum value from
0x0000 to 0x0187.