External IO input request
Message ID
Message name
Description
0x00000007
External IO input request
Message to send to the SC-10A when the
work item is waiting in check mode.
Perform an operation equivalent to EXTIN of
the external IO.
Message format
Address
bit
31
16
15
0
0x0000
Message ID
0x0004
Device ID
0x0008
Device name
0x0048
Work ID
0x0088
reserve
EXTI
N3
EXTI
N2
EXTI
N1
Address
Size
Attribute
Field name
Description
0x0000
4 byte
uint32
Message ID
Message unique ID
0x0004
4 byte
uint32
Device ID
Use the lower 4 bytes of the MAC address
of the SC-10A.
0x0008 - 0x0047
64 byte
char
Device name
Up to 50 half-width alphanumeric
characters long
0x0048 - 0x0087
64 byte
char
Work ID
Up to 50 half-width alphanumeric
characters long
0x0088
4 byte
uint32
External IO
Bit field