RICOH SC-10 SERIES
Socket Mode Function Operating Instructions Ver.1.0.0
32/66
Message ID (Request Response Message: SC-
10A → Other Device)
Work ID start response
Message ID
Message name
Description
0x10000001
Work ID start response
Message sent from the other device as a
response to the work ID start request.
The result and error code are entered in the
response message.
If the result is failed, a code indicating the
cause is added to the error code.
Message format
Address
bit
31
16
15
0
0x0000
Message ID
0x0004
Device ID
0x0008
Device name
0x0048
Year
Month
Day
0x004c
Hour
Minute
Second
reserve
0x0050
Result
Error code
0x0048
Work ID
Address
Size
Attribute
Field name
Description
0x0000
4 byte
uint32
Message ID
Message unique ID
0x0004
4 byte
uint32
Device ID
Equipment unique ID
0x000c - 0x0044
64 byte
char
Device name
Up to 50 half-width alphanumeric
characters long
0x0048
2 byte
uint16
Year
Set the time of the SC-10A.
0x004a
1 byte
uchar
Month
Set 1 to 12 for the time of the SC-10A.
0x004b
1 byte
uchar
Day
Set 1 to 31 for the time of the SC-10A.
0x004c
1 byte
uchar
Hour
Set 0 to 23 for the time of the SC-10A.
0x004d
1 byte
uchar
Minute
Set 0 to 59 for the time of the SC-10A.
0x004e
1 byte
uchar
Second
Set 0 to 59 for the time of the SC-10A.
0x004f
1 byte
uchar
reserve
Unused area
0x0050
2 byte
int16
Result
0: OK
-1: Failed
0x0052
2 byte
uint16
Error code
Refer to
4.Error Code (P.52)
.
0x0054
– 0x0092
64 byte
char
Work ID
Up to 50 half-width alphanumeric
characters long