Service Call
M160/M161
6-38
SM
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
----
Others
Error in the OS
Others
"init died", "vm_pageout: VM is full", "Cache Error”
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC820-00
D
Self-diagnostics error: CPU
[XXXX]: Detailed error code
[0001] to [06FF]
[0801] to [4005]
CPU error
During the self-diagnosis, the controller CPU detects an error.
There are 47 types of error code (0001 to 4005) depending on
the cause of the error. The CPU detects an error and displays
the specific error code with the program address where the error
occurs.
System firmware problem
Defective controller
1. Turn the main power switch off and on.
2. Reinstall the controller system firmware.
3. Replace the controller.
When the problem cannot be fixed with the above procedure,
the following information displayed on the screen needs to be
reported to the technical support center.
- SC code
- Detailed error code
- Program address
[0701] to [070A]
CPU/Memory Error
System firmware problem
Defective RAM-DIMM
Defective controller
Содержание M160
Страница 1: ...SERVICE MANUAL M160 M161 ...
Страница 14: ......
Страница 18: ......
Страница 19: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Страница 20: ......
Страница 28: ......
Страница 29: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None ...
Страница 30: ......
Страница 38: ...Main Machine Installation M160 M161 2 8 SM 9 Input the password 10 Press OK 11 Confirm the password ...
Страница 115: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Страница 116: ......
Страница 122: ......
Страница 123: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None ...
Страница 124: ......
Страница 144: ...PCDU M160 M161 4 20 SM 4 5 PCDU 4 5 1 PCDU 1 Open the front cover A 2 Hold the grip to pull the PCDU A out ...
Страница 158: ...Fusing M160 M161 4 34 SM 4 Two brackets A 5 Fusing lamp A ...
Страница 170: ...Paper Feed M160 M161 4 46 SM ...
Страница 176: ...Paper Transport M160 M161 4 52 SM ...
Страница 189: ...Electrical Components SM 4 65 M160 M161 Replacement and Adjustment 4 12 10HVPS 1 Left Cover page 4 7 ...
Страница 190: ...Electrical Components M160 M161 4 66 SM Left Cover 2 HVPS A x4 x2 Tab x1 4 12 11HVPS WITH BRACKET 1 Left Cover page 4 7 ...
Страница 210: ...ARDF M160 M161 4 86 SM 5 Release the link A of the junction gate solenoid 6 Junction Gate Solenoid A ...
Страница 218: ......
Страница 219: ...SYSTEM MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Страница 220: ......
Страница 242: ......
Страница 243: ...TROUBLESHOOTING REVISION HISTORY Page Date Added Updated New None ...
Страница 244: ......
Страница 366: ......
Страница 367: ...ENERGY SAVE REVISION HISTORY Page Date Added Updated New None ...
Страница 368: ......
Страница 378: ...M160 M161 SERVICE MANUAL APPENDICES ...
Страница 379: ......
Страница 382: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None ...
Страница 383: ......
Страница 402: ...APPENDICES PREVENTIVE MAINTENANCE TABLES REVISION HISTORY Page Date Added Updated New None ...
Страница 403: ......
Страница 412: ...APPENDICES SP MODE TABLES REVISION HISTORY Page Date Added Updated New None ...
Страница 413: ......
Страница 647: ...M160 M161 FAX OPTION REVISION HISTORY Page Date Added Updated New None ...
Страница 648: ......
Страница 652: ......
Страница 656: ......
Страница 812: ...Fax Communication Features SM 156 M160 M161 Fax Option Report Sample ...
Страница 820: ...M440 M441 PAPER FEED UNIT PB1070 PAPER FEED UNIT PB1060 REVISION HISTORY Page Date Added Updated New None ...
Страница 821: ......
Страница 823: ......