Service Call
SM
6-7
M156/M157/M176/M177
T
ro
u
b
le
s
h
o
o
ti
n
g
Defective fusing relay
Defective fusing relay circuit
S24V fuse on the PSU
Unstable power supply.
1. Check the power supply source.
2. Replace the +24V fuse on the PSU.
3. Replace the PSU
559
Fuser 3times jam error
The paper jam counter for the fusing unit reaches 3. The paper jam counter is
cleared if the paper is fed correctly.
This SC is activated only when this function is enabled with "Engine
Maintenance" (default "OFF").
Defective fusing unit
Defective fusing control
1. Clear this SC to send a command after a jam removal.
2. Turn off this function after a jam removal.
Execute "Fuser SC Reset" to recover the machine after completing the
recovery procedure. Otherwise, the machine continues to issue this SC
code and cannot be operated.
SC 6xx (Communication and Other Error)
669
EEPROM communication error
An unexpected value exists in the initialization flag of the EEPROM
EEPROM not connected
Defective EEPROM
1. Installing the EEPROM.
2. Replacing the EEPROM.
Содержание M156
Страница 1: ...M156 M157 M176 M177 SERVICE MANUAL ...
Страница 14: ...PRODUCT INFORMATION REVISION HISTORY Page Date Added Updated New None ...
Страница 19: ...INSTALLATION REVISION HISTORY Page Date Added Updated New None ...
Страница 22: ...PREVENTIVE MAINTENANCE REVISION HISTORY Page Date Added Updated New None ...
Страница 29: ...REPLACEMENT AND ADJUSTMENT REVISION HISTORY Page Date Added Updated New None ...
Страница 87: ...SERVICE TABLES REVISION HISTORY Page Date Added Updated New None ...
Страница 116: ...TROUBLESHOOTING REVISION HISTORY Page Date Added Updated New None ...
Страница 136: ...ENERGY SAVE REVISION HISTORY Page Date Added Updated New None ...
Страница 143: ...M156 M157 M176 M177 SERVICE MANUAL APPENDICES ...
Страница 145: ...APPENDIX SPECIFICATIONS REVISION HISTORY Page Date Added Updated New None ...
Страница 154: ...ERROR MESSAGES REVISION HISTORY Page Date Added Updated New None ...