![Ricoh InfoPrint XT Скачать руководство пользователя страница 95](http://html1.mh-extra.com/html/ricoh/infoprint-xt/infoprint-xt_installation-and-user-manual_1457248095.webp)
nosubmit
Does
not
submit
jobs
to
InfoPrint
Manager.
Note:
Use
this
download
directive
only
at
the
direction
of
a
technical
support
representative.
-j
Controls
whether
pdxtdownload
adds
the
z/OS
job
identifier
as
a
prefix
to
the
input
file
name
before
it
submits
the
job
to
InfoPrint
Manager:
yes
pdxtdownload
adds
the
z/OS
job
identifier
to
the
input
file
name.
This
is
the
default.
no
pdxtdownload
does
not
add
the
z/OS
job
identifier
to
the
input
file
name.
-l
Specifies
what
pdxtdownload
writes
to
the
receiver
log.
For
more
information,
see
“Receiver
log”
on
page
79:
error
pdxtdownload
writes
information
to
the
receiver
log
for
any
jobs
that
had
errors.
It
does
not
write
information
for
jobs
that
completed
processing
successfully.
This
is
the
default.
all
pdxtdownload
writes
information
to
the
receiver
log
for
all
jobs.
none
pdxtdownload
does
not
write
information
to
the
receiver
log.
-m
Specifies
how
InfoPrint
XT
handles
jobs
that
contain
several
data
sets:
1document
pdxtdownload
submits
the
data
sets
to
InfoPrint
Manager
as
a
single
job
that
contains
a
single
document.
Use
this
directive
for
Xerox
LCDS
and
metacode
data
sets.
pdxtdownload
creates
the
single
document
by
concatenating
all
the
data
sets
together
in
a
single
file.
If
the
JCL
specified
a
number
of
copies,
the
file
contains
the
copies.
1document
is
the
default.
1jobcop
pdxtdownload
submits
the
data
sets
to
InfoPrint
Manager
as
a
single
job
that
contains
one
document
for
each
data
set.
If
the
JCL
specified
a
number
of
copies,
pdxtdownload
sets
the
copy-count
document
attribute.
Use
this
directive
for
data
sets
that
contain
data
streams
other
than
Xerox
LCDS
or
metacode,
such
as
PCL
or
PostScript
data
sets.
Notes:
1.
This
publication
does
not
go
into
detail
about
processing
PCL
or
PostScript
jobs.
Also,
make
sure
that
z/OS
does
not
prepend
record-length
information
to
each
record
in
the
job.
InfoPrint
Manager
recognizes
PCL
and
PostScript
data
by
the
values
in
the
first
bytes
of
the
job.
Record-length
information
prevents
InfoPrint
Manager
from
correctly
identifying
the
type
of
data.
2.
Because
Xerox
data
streams
are
record-oriented,
they
require
record-length
information
to
distinguish
between
the
individual
records,
if
the
records
vary
in
length.
Non-Xerox
data
streams,
such
as
PCL
and
PostScript,
are
stream-oriented,
so
record
lengths
corrupt
the
data
stream.
1jobdup
pdxtdownload
submits
the
data
sets
to
InfoPrint
Manager
as
a
Chapter
6.
Transferring
jobs
with
Download
for
z/OS
75
Содержание InfoPrint XT
Страница 1: ...InfoPrint XT for Windows Installation Guide and User s Guide V ersion 2 Release 1 GLD0 0025 01...
Страница 2: ......
Страница 3: ...InfoPrint XT for Windows Installation Guide and User s Guide V ersion 2 Release 1 GLD0 0025 01...
Страница 7: ...InfoPrint Solutions Company printers 172 Index 173 Contents v...
Страница 8: ...vi InfoPrint XT Guide...
Страница 10: ...viii InfoPrint XT Guide...
Страница 12: ...x InfoPrint XT Guide...
Страница 56: ...36 InfoPrint XT Guide...
Страница 78: ...58 InfoPrint XT Guide...
Страница 102: ...82 InfoPrint XT Guide...
Страница 124: ...104 InfoPrint XT Guide...
Страница 136: ...116 InfoPrint XT Guide...
Страница 166: ...146 InfoPrint XT Guide...
Страница 178: ...158 InfoPrint XT Guide...
Страница 186: ...166 InfoPrint XT Guide...
Страница 201: ......
Страница 202: ...Program Number 5799 RZA Printed in USA GLD0 0025 01...