DIP SWITCH SETTINGS
22 December 1998
4-4
Table D: Self Diagnostic Mode
During the self-diagnostic mode, the scanner performs the following tests.
1) Home position error check
2) Exposure lamp error check
3) White level error check
4) Document table error check
5) SCU error check
6) RCU error check
7) IPU error check
8) CIS LEDs error check
9) Memory error check
If the scanner detects errors, the first error that occurred is indicated by a
combination of four LEDs.
LEDs
Error Items
Power On
(Green)
Machine
Busy (Green)
Document in
Place (Green)
Error
(Red)
SCU error
Blinking
—
—
Blinking
RCU error
Blinking
—
On
Blinking
IPU error
Blinking
On
—
Blinking
Home position error
Blinking
Blinking
Blinking
On
Exposure lamp error
Blinking
Blinking
On
On
White level error
Blinking
Blinking
—
—
CIS Leds error
Blinking
Blinking
On
Blinking
Memory error (Simplex)
Blinking
—
—
—
Memory error (Duplex)
—
Blinking
—
—
On: LED on Blinking: LED blinking —: LED off
Table E: Counter Indication Mode
Rotary Switch Table
SCSI ID Rotary Switch No.
Contents
0
Not used
1
Units
2
Tens
3
Hundreds
4
Thousands
5
Ten thousands
6
Hundred thousands
7
Millions
8
Not used
9
Not used