SERVICE CALL CODES
1 July, 1998
4-8
Code
Title
Conditions
Possible Causes
SC05-31 Drum thermistor
short
The thermistor beside the ink
detecting pins detects an
excessively high temperature (96
°
C).
•
Thermistor short
SC05-32 Ink pump sensor
remains on
The sensor is not de-activated
after the ink pump motor on
signal is generated.
•
Defective sensor
•
Defective motor
•
Jammed ink pump
drive
SC05-33 Ink pump sensor
remains off
The sensor is not activated after
the ink pump motor on signal is
generated.
•
Defective sensor
•
Defective motor
•
Jammed ink pump
drive
SC05-40 A4 cam sensor
remains on
The sensor does not de-activate
for more than 6 seconds after the
pressure cam shift motor on
signal is generated.
•
Defective sensor
•
Defective motor
SC05-41 A3 cam sensor
remains off
The sensor does not activate for
more than 6 seconds after the
pressure cam shift motor on
signal is generated.
•
Defective sensor
•
Defective motor
SC05-42 A3 cam sensor
remains on
The sensor does not de-activate
for more than 6 seconds after the
pressure cam shift motor on
signal is generated.
•
Defective sensor
•
Defective motor
SC05-43 A4 cam sensor
remains off
The sensor does not activate for
more than 6 seconds after the
pressure cam shift motor on
signal is generated.
•
Defective sensor
•
Defective motor
SC05-50 Clamper close
position sensor
remains on when
opening the
clamper
At the master clamper open
timing, the sensor is not de-
activated for more than 4
seconds after the clamper motor
on signal is generated.
•
Defective sensor
•
Defective motor
•
Jammed drum guide
drive
•
Defective 2nd drum
position sensor
SC05-51 Clamper open
position sensor
remains off when
opening the
clamper
At the master clamper open
timing, the sensor is not activated
for more than 4 seconds after the
clamper motor on signal is
generated.
•
Defective sensor
•
Defective motor
•
Jammed drum guide
drive
•
Defective 2nd drum
position sensor
SC05-52 Clamper open
position sensor
remains on when
opening the
clamper
At the master clamper open
timing, the sensor is not de-
activated for more than 4
seconds after the clamper motor
on signal is generated.
•
Defective sensor
•
Defective motor
•
Jammed drum guide
drive
•
Defective 2nd drum
position sensor
Содержание Gestetner 5450
Страница 1: ...SERVICE MANUAL Machine code C229...
Страница 11: ...MACHINE INTERIOR 1 July 1998 1 6 1 3 MACHINE INTERIOR C229V501 WMF...
Страница 193: ...EXTERIOR 1 July 1998 6 2 6 1 2 REAR AND LEFT COVERS A Rear cover B Left cover C229R512 WMF A B...
Страница 195: ...EXTERIOR 1 July 1998 6 4 6 1 4 INNER COVER AND KNOB COVER A Inner cover B Knob cover C229R511 WMF A B...
Страница 220: ...1 July 1998 MASTER FEED SECTION 6 29 Replacement Adjustment D Duct entrance solenoid C229R064 WMF D...
Страница 304: ...1 July 1998 7 2 Location Map C229S500 WMF...
Страница 305: ...1 July 1998 7 3 P to P Section A C229S501 WMF...
Страница 306: ...1 July 1998 7 4 Section B C229S502 WMF...
Страница 307: ...1 July 1998 7 5 P to P Section C C229S503 WMF...
Страница 308: ...1 July 1998 7 6 Section D C229S504 WMF...
Страница 309: ...1 July 1998 7 7 P to P Section E C229S505 WMF...
Страница 310: ...1 July 1998 7 8 Section F C229S506 WMF...