1 July, 1998
INSTALLATION REQUIREMENTS
3-1
Installation
3. INSTALLATION
3.1 INSTALLATION
REQUIREMENTS
The installation location should be carefully chosen because the environmental
conditions greatly affect the performance of the machine.
3.1.1 REQUIRED ENVIRONMENTAL CONDITIONS
1. Temperature
10 to 30
°
C (50 to 86
°
F)
2. Humidity
20 to 90 % RH
3. Place the machine on a strong and level base. The machine must be level
within 5 mm both front to rear and left to right.
3.1.2 ENVIRONMENTS TO AVOID
1. Locations exposed to direct sunlight or strong light (more than 1,500 lux).
2. Areas with corrosive gases.
3. Dusty
areas.
4. Locations directly exposed to cool air from an air conditioner or reflected heat
from a space heater. (Sudden temperature changes from low to high or vice
versa may cause condensation within the machine.)
3.1.3 POWER CONNECTION
1. Securely connect the power cord to a power source.
2. Make sure that the wall outlet is near the machine and easily accessible.
3. Make sure the plug is firmly inserted in the outlet.
4. Avoid
multiwiring.
5. Voltage must not fluctuate more than 10%.
6. Do not pinch the power cord.
Содержание Gestetner 5450
Страница 1: ...SERVICE MANUAL Machine code C229...
Страница 11: ...MACHINE INTERIOR 1 July 1998 1 6 1 3 MACHINE INTERIOR C229V501 WMF...
Страница 193: ...EXTERIOR 1 July 1998 6 2 6 1 2 REAR AND LEFT COVERS A Rear cover B Left cover C229R512 WMF A B...
Страница 195: ...EXTERIOR 1 July 1998 6 4 6 1 4 INNER COVER AND KNOB COVER A Inner cover B Knob cover C229R511 WMF A B...
Страница 220: ...1 July 1998 MASTER FEED SECTION 6 29 Replacement Adjustment D Duct entrance solenoid C229R064 WMF D...
Страница 304: ...1 July 1998 7 2 Location Map C229S500 WMF...
Страница 305: ...1 July 1998 7 3 P to P Section A C229S501 WMF...
Страница 306: ...1 July 1998 7 4 Section B C229S502 WMF...
Страница 307: ...1 July 1998 7 5 P to P Section C C229S503 WMF...
Страница 308: ...1 July 1998 7 6 Section D C229S504 WMF...
Страница 309: ...1 July 1998 7 7 P to P Section E C229S505 WMF...
Страница 310: ...1 July 1998 7 8 Section F C229S506 WMF...