8000AC(H) - User parameter switch 12
Bits 0 and 1: Not used
Bit 2: Toner saving mode
0: Disabled, 1: Enabled
Bits 3 and 4: Printout image density (Fax mode)
Bit 4 3 Setting
0 0 Normal
0 1 Lighten
1 0 Darken
1 1 Not used
Bits 5 to 7: Not used
8000AD(H) - User parameter switch 13
Bits 0 and 1: PSTN access method from behind PABX
Bit 1 0 Setting
0 0 PSTN
0 1 Loop start
1 0 Ground start
1 1 Flash start
8000AE - 8000AF(H) - User parameter 14 to 15
Not used
8000B9(H) - User function 62 settings
Bit 0: Night timer
0: Disabled, 1: Enabled
Bits 1 to 3: Not used
Bit 4: RDS operation
0: Not acceptable
1: Acceptable for the limit specified by
system switch 03
Bits 5 and 6: Not used
Bit 7: Daylight saving time
0: Disabled, 1: Enabled
8000BA(H) - User function 62 settings
Bit 0: Not used
Bit 1: Dialing type 0: Pulse dialing (10 pps), 1: Tone (DTMF) dialing
Bits 2 to 7: Not used
8000BB(H) - PSTN access number for loop start
Access number Hex value to program (BCD)
0 F0
ò
ò
0 F0
00 00
ò
ò
99 99
8000C8 to 8000DB(H) - RTI (Max. 20 characters - ASCII) - Note 1
8000DC to 8000EF(H) - CSI (Max. 20 characters - ASCII)
8000F0 to 80010F(H) - TTI (Max. 32 characters - ASCII) - Note 1
800110(H) - Number of CSI characters (Hex)
Note 1: If the number of characters are less than the maxumum (20 for RTI, 32 for TTI), add
a stop code (FF[H]) after the last character.
800111 to 80011F(H) - Service station’s fax number (Service function 13)
800120 to 80012E(H) - Own fax number (User function 61)
SERVICE TABLES AND PROCEDURES
August 2nd, 1995
SERVICE RAM ADDRESSES
4-76