Communication Switch 06
No
FUNCTION
COMMENTS
0
Dialing requirements:
Germany
0: Disabled 1: Enabled
These switches are automatically set to the settings
required by each country after a country code (System
Switch 0F) is programmed.
1
Dialing requirements: Austria
0: Disabled 1: Enabled
2
Dialing requirements:
Norway
0: Disabled 1: Enabled
3
Dialing requirements:
Denmark
0: Disabled 1: Enabled
4
Dialing requirements: France
0: Disabled 1: Enabled
5
Dialing requirements:
Switzerland
0: Disabled 1: Enabled
6
Not used
Do not change the settings.
7
Communication Switch 07 - Not used (do not change the settings)
Communication Switch 08 - Not used (do not change the settings)
Communication Switch 09 - Not used (do not change the settings)
Communication Switch 0A
No
FUNCTION
COMMENTS
0
Point of resumption of
memory transmission upon
redialing
0: From the error page
1: From page 1
0: The transmission begins from the page where
transmission failed the previous time.
1: Transmission begins from the first page.
1
to
6
Not used
Do not change the settings.
7
Emergency calls using 999
0: Enabled 1: Disabled
If this bit is at 1, the machine will not allow you to dial
999 at the auto-dialer. This is a PTT requirement in the
UK and some other countries.
Communication Switch 0B - Not used (do not change the settings)
Communication Switch 0C - Not used (do not change the settings)
August 2nd, 1995
SERVICE TABLES AND PROCEDURES
BIT SWITCHES
4-33