E.2. SCANNER CONTROL INTERFACE
E.2.1. Specifications
Communication method:
EIA RS-232C equivalent
Transmission Method:
Half duplex transmission
Synchronization Method: Start-stop transmission
Data Length:
8 bits
Stop Bit:
1 bit
Parity Check:
Odd parity
Data Rate (bps):
2400, 4800, 9600, 19200
(Default: 4800)
Maximum Cable Length:
5 m
E.2.2. Signal Description
TxD: Response to the command from the host (scanner to host)
RxD: Command from the host (host to scanner)
RTS: The scanner requests to send data to the host (scanner to host)
CTS: The host is ready to receive data from the scanner (host to scanner)
DTR: The scanner is ready to send or receive data (scanner to host)
DSR: The host is ready to send or receive data (host to scanner)
Host
VIU
Control I/F
TxD
RxD
RTS
CTS
DTR
DSR
G404O503.WMF
VIU (VIDEO INTERFACE UNIT)
October 9th, 1995
SCANNER CONTROL INTERFACE